Import-Export Bulletin Board  

Home > Offers to Sell > Telecommunications & Networks > Networking Equipment > Other Wireless Networking Equipment

Contact: chavien.supplies
Company: chavien supplies limited
kuala lumpur,
kuala lumpur 41650
Malaysia
Phone: 60712625271
Fax: 60712452721
E-Mail: Send Inquiry
Date/Time:  7/24/17 13:58 GMT
 

Agilent 53220A Universal Frequency Counter $1,500 USD

message us chavien.supplies@asia.com

Agilent 53220A Universal Frequency Counter in stock for $1,500 USD
per unit

Specifications

Agilent 53220A Universal digital Frequency Counters

Agilent 53220A Universal digital Frequency Counters

Agilent 53220A Universal Frequency Counter Timer 350 MHz . The 53220A
350 MHz universal frequency counter/timer is a two-channel frequency
counter with the ability to make all the frequency and time interval
measurements you depend on. An optional microwave channel can be
added to measure 6 or 15 GHz.

Frequency counters are depended on in R&D and in manufacturing for
the fastest, most accurate frequency and time interval measurements.
The 53200 Series of RF and universal frequency counter/timers expands
on this expectation to provide you with the most information,
connectivity and new measurement capabilities, while building on the
speed and accuracy you’ve depended on with Agilent’s decades of time
and frequency measurement expertise.
Features

Two 350 MHz input channels, plus optional third channel (6 GHz or 15
GHz)
12 digits/second resolution, 100 psec time interval resolution
LXI-C/LAN, USB, GPIB
Built-in math analysis and color, graphical display (trend and
histogram)
Optional: Lithium Ion Battery


Input Channel Characteristics
Input characteristics (nom)
Channels
Standard (DC - 350 MHz) Ch 1 & Ch 2
Optional (6 or 15 GHz) Ch 3
Standard inputs (nom)
Frequency range
DC coupled DC (1 mHz) to 350 MHz (2.8 ns to 1000 sec)
AC coupled, 50 Ω 1 or 1 MΩ 10 Hz - 350 MHz
Input
Connector Front panel BNC(f). Option 201 adds parallel rear panel
BNC(f) inputs 2
Input impedance (typ) Selectable 1 MO ± 1.5% or 50 O ± 1.5% <25
pF
Input coupling Selectable DC or AC
Input filter Selectable 100 kHz cut-off frequency low pass
10 Hz (AC coupling) cut-off frequency high pass filter
Amplitude range
Input range ±5 V (±50 V) full scale ranges
Sensitivity¾ (typ) DC - 100 MHz: 20 mVpk
> 100 MHz: 40 mVpk
Noise³ DC - 100 MHz: 20 mVpk
> 100 MHz: 40 mVpk
Input event thresholds
Threshold levels ±5 V (±50 V) in 2.5 mV (25 mV) steps
Noise reject ±5 V (±50 V) in 2.5 mV (25 mV) steps
Slope Selectable Positive or Negative
Auto-scale Acquires signal for current measurement channel,
selects range (5 V or 50 V), sets auto-level 50%
Auto-level Selectable On or Off
On: Sets auto-level (% of Vpp) operation
Occurs once for each INIT or after a timeout.
Measures signal Vpp and sets Trigger level to 50%
Off: Selectable user set level (Volts)
Minimum signal frequency
for auto level User selectable (Slow (50 Hz), Fast (10 kHz))
Minimum signal for auto
level 300 mVpp
Maximum input
50 Ω damage level 1 W
50 Ω protection threshold Will not activate below 7.5 Vpk
50 Ω internal termination auto-protects
by switching to 1 M Ω
1M Ω damage level DC - 5 kHz: 350 Vpk (AC + DC)
5 kHz - 100 kHz: Derate linearly to 10 Vpk (AC + DC)
>100 kHz: 10 Vpk (AC + DC)
Optional microwave inputs (nom)
Frequency range
Option 106 100 MHz - 6 GHz
Option 115 300 MHz - 15 GHz
Input
Connector Front panel precision Type-N(f)
Option 203 moves the input connector to a rear panel SMA(f)
Input impedance (typ) 50 Ω ± 1.5% (SWR < 2.5)
Input coupling AC
Continuous wave amplitude range
Option 106 Autoranged to +19 dBm max. (2 Vrms)
Option 115 Autoranged to +13 dBm max. (1.0 Vrms)
Sensitivity (typ) 6 GHz (Opt 106): -27 dBm (10 mVrms)
15 GHz (Opt 115):
< 3 GHz: -23 dBm
3 – 11 GHz: -27 dBm
> 11 GHz: -21 dBm
Input event thresholds
Level range Auto-ranged for optimum sensitivity and bandwidth
AM tolerance AM tolerance
Maximum input
Damage level 6 GHz (Opt 106): > +27 dBm (5 Vrms)
15 GHz (Opt 115): > +19 dBm (2 Vrms)
1. AC coupling occurs after 50 O termination.
2. When ordered with optional rear terminals, the standard/baseband
channel inputs are active on both the front and rear of the
universal counter though the specifications provided only apply to
the rear terminals. Performance for the front terminals with rear
terminals installed is not specified.
3. Multiply value(s) by 10 for the 50 V range.
4. Stated specification assumes Noise Reject OFF. Noise Reject ON
doubles the sensitivity minimum voltage levels.
5. Assumes sine wave.
6. CW only. Assumes AM Rate > 10/gate. For Option 106, spec applies
for input powers > -20 dBm; use a tolerance of 15% modulation
depth for frequencies less than 900 MHz. For Option 115, spec applies
for input powers > -10 dBm.

Minimum Order: 1 pieces

Agilent 53220A Universal Frequency Counter $1,500 USD
Enlarge Click to Enlarge
SOURCE: Import-Export Bulletin Board (http://www.imexbb.com/)
Report Abuse

Involved in International Trade? Become an Advertiser!

Post an Offer to Sell

© 1996-2010 IMEXBB.com. All rights reserved.

IMEXBB.com