Import-Export Bulletin Board Post an Offer to Sell

New here? Please subscribe
to post trade leads. It's FREE!

Examination & Testing Instruments


Home > Offers to Sell > Health & Beauty > Medical Supplies > Examination & Testing Instruments

Browse leads by category:
  Examination & Testing Instruments  
Hot & Cold Packs    
    
  Wristbands  
  

Summary of 4/24/24 23:59 GMT:>> Show Compact View
12/29/23 3:02 GMT
DNA Isothermal Amplification Kit NFO With 500-1000 Copies/UL Detection Limi

Product Description Amp-future DNA Isothermal Amplification Kit NFO with 500-1000copies/µL Detection Limit, 48 Tests/box, -20°C Storage Product Detail Kit Storage and term of Validity Storage term: stored at ≤-20℃,keep away from light, avoid heavy weight and repeated freezing and thawing. Term of Validity: 14 months Isothermal nucleic acid Principle Summary The kit is based on room and constant temperature nucleic acid rapid amplification technology, its principle is that at room and constant temperature, the recombinase and primer form a protein/single-stranded nucleotide complex Rec/ssDNA, and invade the double-stranded DNA template with the help of auxiliary proteins and single-stranded binding protein SSB; then form a D-loop region at the invasion point and start to scan the DNA duplex, after finding the target region complementary to the primer and disintegration of the complex Rec/ssDNA, the polymerase also binds to the 3' end of the primer to start the chain extension. The kit relies on the role of NFO enzyme and adds the designed specific molecular probes according to the template, and get the result by colloidal gold technology (sandwich method). Technical Parameters: Parameters Details Product Name DNA Isothermal Amplification Kit NFO Manufacturer Amp-future Storage Temperature -20°C Kit Components Enzymes, Buffers ,Reagents Packaging 48 Tests/box Detection Limit 500-1000copies/µL Shipping ICE Test Time 5-20mins Isothermal nucleic acid Product Features 1/ High sensitivity and specificity, short reaction time. 2/ The reagent form is freeze-dried, stable and easy to operate. 3/ The reaction can be operated by metal bath and water bath pot without purchasing expensive PCR apparatus. Isothermal nucleic acid Applications Suitable for DNA isothermal rapid amplification kit(NFO type) Primer: Require pair of nucleotide primers with the length of 25-35 bp. DNA basic kit reaction temperature is 39 to 42℃ and time is 5-20 minutes. Notes 1/ Please avoid nucleic acid contamination and set blank control during reaction due to the high sensitivity of the kit. 2/ Please take out the required quantity of MIRA reaction units for the experiment, and put the rest under storage conditions when performing the experiment.

Contact:
Phone:
Fax:
Email:
Miss. Oliveria
86-151-50191825
86-151-50191825
Send Inquiry
Amp-Future (Changzhou) Biotech Co., Ltd.
Floor 4, Building 9#, Innovation Park, Changzhou, Israel, China, No. 18-67, Changwu Middle Road, Wujin District, Changzhou City, Jiangsu Province
Changzhou 213000
China
5/24/23 8:44 GMT
QBit 9 Smart Ultrasound for Sale

QBit 9 provides you with an enjoyable and intuitive operating experience. It’s your complete solution for ultrasound diagnosis. Operating system is uncluttered and simple allowing you to provide fast accurate diagnosis. Features Professional Clinical Applications ● ABD ● OB / GYN ● Vascular ● MSK ● Small Parts ● Urology ● Pediatrics ● Cardiac Image Processing Technologies ● Speckle Reduction Algorithm (SRA) ● Multiple Compound Imaging (MCI) ● Q-image ● Q-flow ● X-contrast ● Q-beam ● FHI ● Super Needle

Contact:
Phone:
Fax:
Email:
chison
+86 510 8531 0012

Send Inquiry
CHISON Medical Technologies Co., Ltd
No.3, Xinwu District
Wuxi 214115
China
5/24/23 8:43 GMT
Ultrasound Cartbased machine

XBit 90 A level up in Imaging with premium ultrasound system. √ Ultimate imaging solutions driven by latest NIT platform. √ State of the art technology and diversified intelligent features. √ Extreme accuracy and convenience improve your diagnostic confidence. Specifications · Latest NIT platform · Verstile transducers · 23.8 inch super large HD LED · Internal Battery · 13.3 inch high responsive HD touch panel · Fast and reliable after-sales service · 360° rotatable screen · Ergonomic design to fit different working habits CHISON premium trolly color doppler XBit 90 is designed to offer medical practitioners contemporary and state of the art experience in clinical diagnosis, delivering enhanced views, modern artificial intelligence, and smooth workflow. Featuring the state of the art technology, CHISON cart-based ultrasound XBit 90 is your best choice in the application of General Imaging.

Contact:
Phone:
Fax:
Email:
chison
+86 510 8531 0012

Send Inquiry
CHISON Medical Technologies Co., Ltd
No.3, Xinwu District
Wuxi 214115
China
5/24/23 8:42 GMT
Pocket Ultrasound

SonoEye P2 CHISON SonoEye can help to provide high quality patient care in any location. Featuring an adaptable design that goes from pad to mobile phone, increasing the portability, and making it possible to work together with doctors from patient to patient all the time, initially in point of care applications and longer terms in primary care. Go Light Half weight of a phone, highly integrated design, less volume. Multiple devices SonoEye provides a flexible connection with smart phone or pad. Go Waterproof SonoEye, a hand-held ultrasound, gives you the power to sterilize and clean freely.

Contact:
Phone:
Fax:
Email:
chison
+86 510 8531 0012

Send Inquiry
CHISON Medical Technologies Co., Ltd
No.3, Xinwu District
Wuxi 214115
China
5/24/23 8:40 GMT
Cart-Based Ultrasound

CBit 9 Ergonomic Design 21.5 inch Wide HD LED 10.1 inch Customerized Touch screen Four probe connectors Gel warmer Height adjustable Battery Application Hi , ghly Improved productivity enables the practitioner to explore and expediate the examination with Better diagnostic confidence. Cardiology OB/GYN Radiology Vascular Point-of-Care Key Technology Trends Premium Image Quality

Contact:
Phone:
Fax:
Email:
chison
+86 510 8531 0012

Send Inquiry
CHISON Medical Technologies Co., Ltd
No.3, Xinwu District
Wuxi 214115
China
5/24/23 8:39 GMT
CHISON SonoBook 6 Portable Veterinary Ultrasound

CHISON SonoBook 6 Portable Veterinary Ultrasound Featured with compact laptop based design for easy mobility, provide solutions when fast reaction is needed. Combined with productive features, crisp imaging performance and intuitive workflow, SonoBook 6 could support excellent patient care, and offer economic clinical value. • 15”LED HD monitor, 120° rotatable • Truly portable design (without battery ) approx. 11 lb • Longer battery life up to 2 hours active mode, fast battery swap • Triple probe connector and precision cart(Option) • SonoDocking: DVI-I, Foot-Switch, Video-Out, remote, S-Video, for fast data transfer

Contact:
Phone:
Fax:
Email:
chison
+86 510 8531 0012

Send Inquiry
CHISON Medical Technologies Co., Ltd
No.3, Xinwu District
Wuxi 214115
China
4/20/23 9:00 GMT
16 Panel Self Testing Drug Kits 15 Urine Drug Test Plus Adulterant Strip

16 panel Drug Abuse test kit 15 urine drug test plus adulterant strip Intended Use The Multi-drug Rapid Test Panel (Urine) is rapid chromatographic immunoassays for the qualitative and simultaneous detection up to sixteen of the following drugs in human urine. The designed cutoff concentrations for these drugs are as follows: Test Cut-off (ng/mL) AMP(Amphetamine) 500 THC(Marijuana) 50 COC (Cocaine) 200 PCP(Phencyclidine) 25 MOR(Morphine) 200 MET(Methamphetamine ) 500 MTD(Methadone) 300 BZO(Oxazepam) 200 BUP(Buprenorphine) 5 ETG(Ethylglucoronide) 1000 TML(Tramadol) 100 COT(Cotinine) 300 FYL(Fentanyl) 100 OXY (Oxycodone) 100 PGB (Pregabalin) 500 Adulteration ( Oxidants,Specific Gravity,pH) / Principle The Multi-drug Rapid Test Panel (Urine) is one-step immunoassay in which chemically labeled drugs (drug-protein conjugates) compete for limited antibody binding sites with drugs which may be present in urine. The test panel contains membrane strips which are pre-coated with drug-protein conjugates on the test band(s). Each strip, the drug antibody-colloidal gold conjugate pad is placed at one end of the membrane. In the absence of drug in the urine, the solution of the colored antibody-colloidal gold conjugate move along with the sample solution upward chromatographically by capillary action across the membrane to the immobilized drug-protein conjugate zone on the test band region. The colored antibody-gold conjugate then attach to the drug-protein conjugates to form visible lines as the antibody complex with the drug conjugate. Therefore, the formation of the visible precipitant in the test zone occurs when the test urine is negative for the drug.When the drug is present in the urine, the drug/metabolite antigen competes with drug-protein conjugate on the test band region for the limited antibody. When a sufficient concentration of the drug is present, it will fill the limited antibody binding sites. This will prevent attachment of the colored antibody (drug- protein conjugate)-colloidal gold conjugate to the drug-protein conjugate zone on the test band region. Therefore, absence of the color band on the test region indicates a positive result.A control band with a different antigen/antibody reaction is added to the immunochromatographic membrane strip at the control region (C) to indicate that the test has performed properly. This control line should always appear regardless of the presence of drug or metabolite. If the control line does not appear the test panel should be discarded. Adulteration is the tampering of a urine specimen with the intention of altering the test results. The use of adulterants can cause false negative results in drug tests by either interfering with the screening test and/or destroying the drugs present in the urine. Dilution may also be employed in an attempt to produce false negative drug test results.One of the best ways to test for adulteration or dilution is to determine certain urinary characteristics such as pH, and Specific Gravity and to detect the presence of Oxidants in urine. INTERPRETATION OF RESULTS NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested. *NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line. POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug. INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer. Cross Reactivity A study was conducted to determine the cross-reactivity of the test with compounds in either drug-free urine or drug positive urine containing, Amphetamine, Barbiturates, Benzodiazepines, Buprenorphine, Cocaine, Marijuana, Methadone, Methamphetamine, Methylenedioxymethamphetamine, Morphine, Tramadol , Methaqualone, Ketamine ,Phencyclidine, Propoxyphene or Tricyclic Antidepressants. The following compounds show no cross-reactivity when tested with the Multi-Drug Rapid Test Panel with Adulteration at a concentration of 100 µg/mL. Visual interpretations occurred at 5 minutes after specimen application. Results are presented in table below.

Contact:
Phone:
Fax:
Email:
Mr. Jerry Meng
86-130-22602586
86-573-82033098
Send Inquiry
Orient New Life Medical Co.,Ltd.
12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
Ningbo 315000
China
3/29/23 9:44 GMT
JINGZ Blood Sample Collection Vials 2Ml-10 Ml

Product Description VACUUM BLOOD COLLECTION TUBE JINGZ Vacutainer Blood Sample Collection Tube 2-10ml Glass Plastic EDTA Tube Gel Tube Vacuum blood collection tube is a sterile glass or plastic test tube with a colored rubber stopper creating a vacuum seal inside of the tube, facilitating the drawing of a predetermined volume of liquid. Vacuum blood collection tubes may contain additives designed to stabilize and preserve the specimen prior to analytical testing. Tubes are available with a safety-engineered stopper, with a variety of labeling options and draw volumes. The color of the top indicates the additives in the vial. SPECIFICATION JINGZ Blood Sample Collection Vials 2Ml-10 Ml 0 Shelf Time: 24 months for Glass tube, 12 months for PET Tube Material Size Volume Packing Glass/PET 13*75mm 2-4ml 100pcs/tray, 1200/1800pcs per carton 1million pcs a 20FT container 2million pcs a 40FT container 2.6milion pcs a 40HQ container Glass/PET 13*100mm 5-7ml Glass/PET 16*100mm 8-10ml JINGZ Blood Sample Collection Vials 2Ml-10 Ml 1JINGZ Blood Sample Collection Vials 2Ml-10 Ml 2JINGZ Blood Sample Collection Vials 2Ml-10 Ml 3JINGZ Blood Sample Collection Vials 2Ml-10 Ml 4 JINGZ Blood Sample Collection Vials 2Ml-10 Ml 5 INSTRCUTION FOR USE 1. Check the tube first; 2. Insert the blood collection needle into the vein after the skin disinfection; 3. Put the puncture needle into rubber stopper and the blood will automatically flow into the tube; 4. After the blood is collected to the calibration capacity, first pull out the IV needle on body, then pull off the tube. 5. Gently reverse the tube 5-8 times after collection(except no additive plain tube). JINGZ Blood Sample Collection Vials 2Ml-10 Ml 6JINGZ Blood Sample Collection Vials 2Ml-10 Ml 7 NOTICE 1. The needle should vertically piercing in the middle of rubber stopper; 2.Single use only. Discard after use; 3. It is prohibited to use the tube which are contaminated or have impurities in it; 4. In order to prevent blood spatter or avoid blood infection the operators should wear gloves and other protective devices; STORAGE 1. The vacuum blood collection tubes should be stored in cool dry place at 0℃-25℃; 2. The vacuum blood collection tubes shall be vertical and prohibited to invert. FAQ 1. Are you factory or trading company? We are a factory established in 2005 under the name of Jiangxi Exquisite(JINGZ) Technology Co.Ltd in Jiangxi Xiaolan Industrial Park, with full production line and medical approval certificates. YBK Medical is the subsidary company of JINGZ to supply better sales and service to customers. 2. How can I contact your company? Email us at jingz08@jxjzkj.cn, ivy.du@ybkmed.com or Whatsapp: 008615084880052. Welcome to visit our factory at Nanchang too. 3. Do you have an MOQ for blood tube and needle? Yes, MOQ 12000pcs(10 cartons) for each size. 4. Is it ok to print our logo on label and packing carton? Yes, we offer OEM/ODM service for our products. But OEM MOQ needs 200,000pcs.

Contact:
Phone:
Fax:
Email:
Ms. Ivy Du
86-731-86801353
86-731-86801353
Send Inquiry
Hunan YBK Medical Technology Co., Ltd.
No.80 Fuzhong Road,Langli Street,Changsha,Hunan,China
Changsha 410000
China
2/28/23 7:51 GMT
CRP Rapid Test Cassette Diagnostic Blood Tests Rapid Chromatographic Immuno

A rapid test for the diagnosis of inflammatory condition by detecting CRP qualitatively in whole blood, serum or plasma CE certified Applications: The CRP Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human CRP in whole blood, serum or plasma as an aid in the diagnosis of inflammatory condition. The cut-off of the test is 10 μg/ml. Description: C-reactive Protein (CrP) in patient’s sera has been found in association with acute infections, necrotic conditions and a variety of inflammatory disorders. There is a strong correlation between serum levels of CrP and the onset of the inflammatory process. Monitoring the levels of CrP in patient’s sera indicates the effectiveness of treatment and the assessment of patient recovery. It is used in particular to differentiate bacterial infections from virus infections. How to use? Bring tests, specimens, buffer, and/or controls to room temperature (15-30°C) before use. 1. Remove the Test Cassette from its sealed pouch, and place it on a clean, level surface. For best results, the assay should be performed within one hour. 2. Open the tube with the diluted sample .Transfer 3 drops(approximately 120µL)of mixed specimens to sample well. Start the timer. 3. Wait for the colored lines to appear. The result should be read at 5 minutes. Do not interpret the result at 10 minutes. CRP Rapid Test Cassette Diagnostic Blood Tests Rapid Chromatographic Immunoassay 0 INTERPRETATION OF RESULTS (Please refer to the illustration above) POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T). *NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of CRP antigen present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive. NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor. NOTE: 1. The intensity of the color in the test region (T) may vary depending on the concentration of analytes present in the specimen. Therefore, any shade of color in the test region should be considered positive. Please note that this is a qualitatively test only, and cannot determine the concentration of analytes in the specimen. 2. Insufficient specimen volume, incorrect operating procedure or expired tests are the most likely reasons for control line failure.

Contact:
Phone:
Fax:
Email:
Mrs. Selina
86-571-56267891
86-571-56267856
Send Inquiry
Hangzhou AllTest Biotech CO.,LTD
550# Yinhai Street, Hangzhou Economy and Development Area
Hangzhou 310000
China
12/30/22 8:47 GMT
Athos

The Athos series patient monitor series are designed to meet daily clinical needs and seamlessly integrate into the hospi- tal workflow. A variety of monitor models have more and more accurate practical clinical application values. In acute care, patient monitors must be reliable, easy to use, have advanced parameters, and allow access to data when needed. When transporting patients, the equipment should be easy to carry. The Athos series of patient monitors are lightweight, powerful, and intuitive in user interface. They are the best choice for acute, in- and out-of-hospital transfers. Features : Monitor should be modular in design, compact and suitable for adult, pediatric and neonates. Standard parameters: SpO2, 12leads ECG, PR, HR, RESP, NIBP,2*TEMP. Optional parameters: EtCO2, 2*IBP, CO. 12.1inches/15.6inches colour LED screen with touch screen and /or rotator knob. Upgradable module is interchangeable (plug and play type). Capable to visualize 6 or more waveform. Support colour coding for different waveform. ST segment analysis with ST trend with continuous display of ST value on screen. Multiple screen layout to view big font size in numeric and waveform. Trending facilities for upto 360 hours of both graphical & numerical along with eventreview facility for all parame- ters and full waveform disclosure facility. Different visual alarm with colour coding and audible alarms for variousparameters with three levels of volume adjustment. Support HL7 protocol to access the central workstation Energy-saving, low-power design, extending battery life Configure noise reduction fan to ensure a quieter and cleaner environment Arrhythmia detection and analysis in various leads. A inbuilt battery backup of 4 hours Specifications : SpO2 : SPO2 Range 0~100% SPO2 Accuracy 70~100%, ±2% <70%, Undefined PI Range 0~20% PVI Range 0.001% PR Range 25-250 bpm PR Accuracy ±2bpm or ±2% ECG : ECG Range 0.15mV~5.5mV ECG Resolution 2.36uV/LSB HR Range 15~300 bpm(adult) 15~250 bpm(child/neonate) HR Accuracy ±1bpm RR Range 0~120 rpm RR Accuracy 15~120rpm : ±2rpm or ±2% <15rpm : Undefined TEMP : Range 0-50°C Accuracy ±1°C Resolution 0.1°C NIBP : Pressure Range 0 ~ 300mmHg Pressure Accuracy ±2mmHg or ±1% of reading (take thelarger value) Resolution 1mmHg SYS Range Adult : 40-270mmHg Pediatric : 40-200mmHg Neonate : 40-130mmHg DIA Range Adult :10-210mmHg Pediatric :10-162mmHg Neonate :10-90mmHg Mean Range Adult : 20-230mmHg Pediatric : 20-170mmHg Neonate : 20-100mmHg Accuracy The mean deviation <±5mmHg The standard deviation <8mmHg IBP(optionel) : Pressure Range -50 ~ 350 mmHg Accuracy ±3mmHg or ±1% of reading PR Range 25-250bpm PR Accuracy ±2 bpm or ±2% (whichever is greater) CO(optionel) : Range 0.20 ~ 20.00L/Min Accuracy ±5% EtCO2(optionel) : CO2 Range 0~20.0 vol% CO2 Accuracy 0~12 vol% : ±(0.2 vol% +2% of reading) 12~20vol% : ±(0.2 vol% + 6% of reading) AwRR Range 0~150 rpm AwRR Accuracy mainstream : 0~150rpm, ±1rpm Sidestream:0~69 rpm, ±1rpm 70~150 rpm, Undefined

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Stéphane HOLLANDE
+33 9 84 116 339

Send Inquiry
Zug Medical Systems
136 chemin des bréguirès
Brignoles 83170
France
12/9/22 2:10 GMT
Polypectomy Snares (Hot & Cold)

Polypectomy snares are indicated for use endoscopically for the removal of polyps. Features of Endoscopy Snares(Hot & Cold) Snares are available in Oval, Hexagon and Half-moon shapes. Hot & cold hybrid function satisfy current doctors desire. 360° 1:1 rotation for precise adjustment. Specification of Hot Snare Polypectomy and Cold Snare Polypectomy Rgeular items REF Catheter Snare Units/Box Fixed Rotatable Catheter Diam. (mm) Working length (mm) Opening Width (mm) Configuration L16CA241806A1 L16RA241806A1 2.4 1800 6 Oval 10 L16CA241808A1 L16RA241808A1 2.4 1800 8 L16CA241810A1 L16RA241810A1 2.4 1800 10 L16CA241815A1 L16RA241815A1 2.4 1800 15 L16CA241825A1 L16RA241825A1 2.4 1800 25 L16CA242406A1 L16RA242406A1 2.4 2400 6 L16CA242408A1 L16RA242408A1 2.4 2400 8 L16CA242410A1 L16RA242410A1 2.4 2400 10 L16CA242415A1 L16RA242415A1 2.4 2400 15 L16CA242425A1 L16RA242425A1 2.4 2400 25 L16CB241810A1 L16RB241810A1 2.4 1800 10 Hexagon L16CB241815A1 L16RB241815A1 2.4 1800 15 L16CB241822A1 L16RB241822A1 2.4 1800 22 L16CB242410A1 L16RB242410A1 2.4 2400 10 L16CB242415A1 L16RB242415A1 2.4 2400 15 L16CB242422A1 L16RB242422A1 2.4 2400 22 What is endoscopy cold snare Endoscopic resection of gastrointestinal polyps is the endoscopic removal of gastrointestinal polyps. There are usually biopsy forceps removal, including cold biopsy forceps and hot biopsy forceps. The excision of the snare includes the excision of the cold snare and the hot snare high frequency electrical snare. In addition, there is submucosal resection. For larger polyps, endoscopic submucosal dissection may be used. It is necessary to consider which method of endoscopic resection should be selected according to the size of the polyp, the location of the growth, and the blood flow. Cold VS Hot Snare Polypectomy Cold snare polypectomy is an easy-to-apply technique and remains the most popular technique, especially for small polyps. According to studies, the complete resection rate of cold snare is very close to or equal to that of hot snare for polyps of 6 to 9 mm. Cold snare can be considered an effective treatment for small polyps, with the advantage that in most cases, cold snare reduces the risk of delayed complications. Thermal snare may be appropriate for occasional 6-9 mm polyps that have thicker stems or have a very prominent sessile component. Cold snare can be very effective and safe when dealing with large numbers of polyps. Cold Hexagonal Snare Polypectomy Technique Advantages of cold snare polypectomy include A. No need to power on B. Easy to operate C. Low complication rate D. No risk of polyp residue E.low cost Now the polypectomy snare price is affordable, if you have needs, please contact us. If you want to know more types of endoscopy device, please visit our website.

Contact:
Phone:
Fax:
Email:
LeoMed
0519-85150730

Send Inquiry
Leo Medical Co., Ltd.
1st & 2nd Floor, 10 Building, 18 Huashan Rd, Changzhou, Jiangsu province, China
Suzhou,China 213022
China
8/15/22 6:42 GMT
Centrifuge DM0636

Centrifuge DM0636 Speed can be set from 300- 6000rpm Maximum capacity of the centrifuge: 100 mLx4 9 Acceleration/10 Brake speed settings to ensure optimal separation A wide range of accessories (fixed angle and swing-out bucket rotors) Key Features of Centrifuge DM0636 Automatic rotor identification Timers can be set up to 99 min. for short-run/ continuous run 9 procedures stored in memory makes the operation much simplified Maintenance-free brushless DC motors Key Features of Centrifuge DM0636 Automatic rotor identification Timers can be set up to 99 min. for short-run/ continuous run 9 procedures stored in memory makes the operation much simplified Maintenance-free brushless DC motors Specifications DM0636 Speed range 300-6000rpm increment:10rpm Max. RCF 4020xg Speed accuracy ±20rpm Max. Capacity 100mLx4 Run Time 30sec-99mins/continuous Motor Brushless DC Display LCD Program Memory 9 Safety Devices Door Imbalance protection Over speed & temperature detection Acceleration/Deceleration time 9↑/10↓steps Power 660W; Single-phase AC220V-240V, 50Hz/60Hz, 6.3A; AC110V-120V, 50Hz/60Hz,10A Dimension[WxDxH] 445x579x269mm Weight 36kg Certification CE Advanced features speed/race switch; Rotor identification As a blood bank centrifuge manufacturer, we have types of blood bank centrifuge for sale, and the blood centrifuge machine price is low, anything you need, please leave us a message. As one of the top healthcare equipment companies, All Trusted provides clients with high quality medical equipment, which can be used in many places, such as hospicals, clinics, healthcare center and so on. We also have types of covid 19 rapid antigen test for sale, if you have needs, please contact us.

Contact:
Phone:
Fax:
Email:
HONVISION
+86 0755-2372 9397

Send Inquiry
SHENZHEN ALL TRUSTED MEDICAL CO., LTD
9A-501, Wutong Island, Hangkong Road, Ban'an District, Shenzhen, China
Shenzhen
China
8/15/22 6:41 GMT
Centrifuge DM0412

Digital Centrifuge DM0412 Easy programming to achieve high accuracy of speed control Easy operation with intuitive menu and easy-to-read display Rotor speed can be set and displayed by RPM or G-force Maintenance-free brushless DC motors Key Features of Centrifuge DM0412 Quick spin function with press and hold pulse key Lid with electric lock and automatic release function saves processing time and prevents samples overheating Automatic self-diagnosis on startup showing accumulative running time and last running parameters Braking time 2 gears adjustable (for A6-50P rotor) A12-10P and A6-50P are not interchangeable Product Parameters of Centrifuge DM0412 Specifications DM0412 Speed Range 300-4500rpm, increment: 100rpm Max. RCF 2490×g Speed accuracy ±20rpm Rotor type A12-10P, A6-50P Run Time 30sec-99min/Continuous Motor Brushless DC moto Display LCD Safety Devices Door interlock, Overspeed detector; Automatic internal diagnosis Acceleration A12-10P: 20s↑13s↓ /Braking time [Sec] A6-50P: 20s↑20 s /90 s↓ Power Single-phase, 110V-240V, 50Hz/60Hz, 3A 70W Dimension [D×W×H] 301×354×217mm Weight 6kg Certification CE, UL, IVD Advanced Features Speed/RCF switch; Short-time run function; sound-alert function Now the price of medical equipment wholesale is affordable, if you have needs, please contact us. If you want to know more types of nucleic acid extraction system, please visit our website.

Contact:
Phone:
Fax:
Email:
HONVISION
+86 0755-2372 9397

Send Inquiry
SHENZHEN ALL TRUSTED MEDICAL CO., LTD
9A-501, Wutong Island, Hangkong Road, Ban'an District, Shenzhen, China
Shenzhen
China
8/15/22 6:41 GMT
Centrifuge DM0408

Centrifuge DM0408 Ideal for microfiltration and quick spin-downs. Easy-to-use with dual start/stop function. Speed range of 300-4000rpm. 3 programs storage capacity for routine applications. Key Features of Automated Centrifuge DM0408 Automatic internal diagnosis. Maintenance-free brushless DC motor. Rotor changes without tools Accelerates and brakes in seconds Available in two colors i.e., green, blue Product Parameters of Centrifuge DM0408 Specifications DM0408 Speed range 300-4000rpm increment: 100rpm Max. RCF 1900×g Speed accuracy ±100rpm Rotor Angel 8×15ml (Default), Angel 10ml×12 Run time 1-99min, HOLD Motor Brushless DC motor Display LED Program Blood: 3200rpm,10min. Urine: 1800rpm,5min. Fecal: 1300rpm,10min. Safety Device Automatic internal diagnosis Acceleration/deceleration 25s↑35s↓ Power Single-phase, 100V-240V, 50Hz/60Hz Dimension(W×D×H) 286×367×227mm Weight 9.2kg Noise ≤60dB(A) As a hospital supply company, we can also provide types of portable x ray machine for sale, if you are interested, please leave us a message.

Contact:
Phone:
Fax:
Email:
HONVISION
+86 0755-2372 9397

Send Inquiry
SHENZHEN ALL TRUSTED MEDICAL CO., LTD
9A-501, Wutong Island, Hangkong Road, Ban'an District, Shenzhen, China
Shenzhen
China
8/15/22 6:39 GMT
Centrifuge D2012plus

Centrifuge D2012plus The powerful horizon centrifuge force of 15100xg and max. speed of 15000rpm ideal for various applications Brushless DC motor drive quickly accelerates the rotor to set speed Quiet working, Low noise ≤56dB Key Features of Centrifuge D2012plus D2012 is proven by IEC/EN 61010-1 D2012 Plus passed the rigorous explosion-proof test and was accredited with CE, cTUVus, FCC certificates, and MCA test. MCA test according to IEC/EN61010-2-20 Product Parameters of Centrifuge D2012plus Specifications D2012 plus Max. Speed 15000rpm(500-15000rpm), increment:100rpm Max. RCF 15100×g, increment: 100×g Speed Accuracy ±20rpm Rotor Capacity 0.2mL/0.5mL/1.5mL/2mL×12 Run Time 30sec-99min/Continuous Driving Motor Brushless DC motor Safety Devices Door interlock, Over-speed detection, Over-temperature detection, Automatic internal diagnosis Power Single-phase, AC100V-240V 50Hz/60Hz, 3A,100W Noise level ≤54dB Acceleration/Braking time 11s↑/9s↓ Dimension[D×W×H] 255×245×140mm Weight 6kg As a healthcare equipment supplier, we can also provide types of real time pcr machine for sale, if you are interested, please leave us a message.

Contact:
Phone:
Fax:
Email:
HONVISION
+86 0755-2372 9397

Send Inquiry
SHENZHEN ALL TRUSTED MEDICAL CO., LTD
9A-501, Wutong Island, Hangkong Road, Ban'an District, Shenzhen, China
Shenzhen
China


SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)
Result Page:   1   |   2  |   3  |   Next >>

Post an Offer to Sell
Home - Offers to Buy - Business Opportunities - Company Profiles

© 1996-2024 IMEXBB.com. All rights reserved.

IMEXBB.com