Waterproof Test Machine for IPX1 to IPX8
JL-X waterproof test machine is according to IEC60529:1989 +A1:1999 +A2:2013 Degrees of protection provided by enclosures(IP Code), IEC60598, IEC60335 and IEC 60034-5, GB/T-2423.2, GB4208, GB7000.1. The JL-X includes the following test grades: IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7 and IPX8 (Refer to page 51 of IEC60529). It is widely used in the authentication test organization for the products such as electrical & electronic products, LED luminaires as well as in the relevant quality control department for the waterproof detection of the enclosures protection grades. The whole JL-X waterproof test system includes: • Drip Box (JL-12): The drip box is for IPX1 and IPX2 drip test. The drip box size is 800x800x45mm (LxWxH). The diameter of drip hole is 0.4mm. The distance between drip holes is 20mm. The sample can be over 150kg. • Swing Pipe Water Spray Test Equipment (JL-34): It is for IPX3 and IPX4 waterproof test. The semi-diameter of swing pipe is 1meter (Any other size is also available). The inside diameter of the swing pipe is 15mm. The sample rotating table diameter is 1000mm (Or other size according to the diameter of the swing pipe), and the height is adjustable. The rotation speed is 1~5rpm which controlled by PLC panel. • Waterproof Jet Test Device (JL-56): With water supply device size is 1000x1000x600mm, the nozzle diameter is ф6.3mm (IPX5 waterproof test ) and ф12.5mm (IPX6 waterproof test). The water speed is 12.5 ±0.626L/min for IPX55 and 100 ±5L/min for IPX6 • Immersion tank Waterproof test Device (JL-7): It is for IPX7 waterproof test. The water tank size is 1000x1000x1200mm (Other size can be designed according to your request). It can test samples up to 120kg. • Immersion tank Waterproof test Device (JL-8): It is for IPX8 test. It can simulate a water depth of 0~50m. The water immersion tank diameter is 600mm and the height is 1200mm. The compressive stress is 10 atmospheres or design according to customer's request. Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/25/23 7:15 GMT
Lamp Start, Run-up time and Flicker Test
LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer - Flicker Tester is equipped with Class A fast photometric probe, so the sampling speed is up to 100kHz. It fully meets the requirement of BASIC, Energy Star V2.1, IEC TR 61547-1:2020 IEC-Pst, CA CEC, ASSIST, CIE TN006-2016 CIE SVM, IEEE Std 1789 standards, etc. It is professional for flicker test of LED lights and lamps, energy-saving lamps, etc. According to EU directives 1194/2012, 2009/125 / EC, SASO2902, COMMISSION DELEGATED REGULATION (EU) 2019/2015, COMMISSION REGULATION (EU) 2019/2020 and IEC60969 "Self-ballasted Lamps for General Lighting Services-Performance Requirements" and other requirements. The LSRF-3 can connects with PC via USB cable. The English version software can be run in Win7, Win8 and Win10, Win11 (The driver was Certificated by Microsoft) Lamp Flicker test interface needs to work with LISUN Integrating Sphere, DC Power Source and Standard Light Source, it also can be added in LISUN LPCE-2 /LPCE-3 Integrating Sphere System or LSG-6000/LSG-1890B/LSG-1800A Goniophotometer or LSG-6000CCD/LSG-1890BCCD/LSG-1800ACCD Goniospectroradiometer. Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/25/23 7:13 GMT
High Precision Rotation Luminaire Goniophotometer
What is goniophotometer definition? LSG-1890B/LSG-1800A goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for rotating the light source. The LSG-1890B/LSG-1800A uses a constant temperature detector, Japanese motor and German precision angle coder which keep the test results with high accuracy. It is for industrial laboratory photometric data measurement of all kinds of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on. Standard: Full meet the EN13032-1 clause 6.1.1.3 goniophotometer type 1, COMMISSION DELEGATED REGULATION (EU) 2019/2015, CIE-70, CIE-121, IES LM-79, IES LM-75, IES LM-80 and ect. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency(Option),Luminance Distribution,Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc. Specification: • The goniophotometric instrument can do the B-β test with two pillars and the C-γ test with single pillar & multi-function jigs • Test Max Luminaires size and weight: LSG-1890B is 2000mm/60kg and LSG-1800A is 1600mm/50kg • The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the tested luminaries rotates around itself with an angle of (C)±180°(or 0- 360°) • Luminosity Testing Range: Illuminance 0.01lx~99,999lx; Light Intensity 1.0cd~10^7cd (detector) • Angle accuracy: LSG-1890B is 0.1°, LSG-1800A is 0.2° • Photometry Accuracy: CIE Class A (Class L is option) • Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1% • English version software can run in Win7, Win8 or Win10, Win11 • LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be transferred by other illumination and luminaire design software such as DiaLux. What are the types of goniophotometer? The types of Goniophotometers can be basically divided into Type A, Type B and Type C. For a detailed description, please refer to the 1987 edition of CIE 70. The difference between them lies in the way the lighting equipment rotates during the measurement and the photometric data obtained during this measurement. How does goniophotometer measures? Goniophotometer is a device used to measure the light distribution performance of lamps. Goniophotometer measures the spatial light intensity distribution of lamps or light sources, total luminous flux and lamp efficiency and other parameters. Goniophotometer need to work in larger darkroom. Use low-reflectivity materials in the room to avoid reflected light from entering the probe. Depending on the arrangement of the measuring light path, two measurement schemes can be used to measure the luminous flux: the illuminance integral method and the luminous intensity integral method. Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/25/23 7:11 GMT
EMI Receiver System
EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPR15:2018, CISPR16-1, GB17743, FCC, EN55015 and EN55022. System Configurations: • EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K- 1GHz), LISN-A Artificial Network Power (16A with RS-232 communicate), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers and cables. • EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN-A Artificial Network Power (5A), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers, Attenuator and cables. • EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN-A Artificial Network Power (5A), 3pcs Isolation Transformers, Attenuator and cables. Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers: • LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Source for EUT • LISUN SDR-2000B Magnetic Shielding Cabinet for the EMI Receiver System • LISUN VVLA-30M Three Loop Antenna to test 9k-30MHz Radiation • LISUN AB-CLP Absorbing Clamp to test the Home Applications & motor tools Specification: • Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA) • Frequency stability: 1×10^-6 • Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz • Test Tolerance: ±2 dB • Measure and Detection method: PK, QP and AV • Measure range from 20dBμV to 140dBμV • Frequency scanning step length: 20Hz~2MHz • Sweep bandwidth: 200Hz; 9kHz; 120kHz • Connect PC via USB cable and software can run on Win7, Win8 and Win10, Win11 What is EMI receiver? Electromagnetic Interference (EMI receiver) is electronic noise that interferes with cable signals and reduces signal integrity. EMI Receiver is usually generated by electromagnetic radiation sources such as motors and machines. EMI Receiver (Electromagnetic Interference) has two types: conducted interference and radiated interference. Conducted interference refers to the coupling (interference) of signals on one electrical network to another electrical network through a conductive medium. Radiated interference refers to the interference source coupling (interference) its signal to another electrical network through space. How to test EMI Interference? Electromagnetic disturbance that degrades the performance of electrical equipment or electronic device, works abnormally or fails. It can be divided into conducted interference test and radiated interference test. LISUN EMI-9KB is an automatic EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. It can do both conducted interference test and radiated interference test. What's the difference between EMI and EMS? EMC (Electro Magnetic Compatibility) literally translates to "electromagnetic compatibility". EMI (Electromagnetic Interference) "Electromagnetic Interference" can be understood as attack type. There are two types of EMI, conducted interference and radiated interference. EMS (Electro Magnetic Susceptibility) literally translates to "electromagnetic sensitivity", which we can understand as defensive type, which means the ease of performance degradation due to electromagnetic energy. Noted: According to latest CISPR15:2018 standard, you need to use CDNE-M316 (Coupling/Decoupling Network for Emission) to instead the CDN. The CDNE-M316 worked with EMI receiver system is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30M-300mHz Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/25/23 7:10 GMT
High Voltage Lightning Surge Generator
Product Description The SG61000-5 fully automatic surge generator (also called lightning surge immunity test, combination wave generator, surge current generator/surge voltage generator, combined surge voltage and current generator) . How does a surge generator work? The SG61000-5 surge generator provides a common basis for evaluating the resistance of power cords and internal connectors of different equipment to high energy transient interference caused by natural lightning surge induction and large capacity load switching. It fully meets the IEC 61000-4-5, EN61000-4- 5 and GB/T17626.5 standards. Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/25/23 7:07 GMT
High Precision Spectroradiometer Integrating Sphere System
LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED's quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3- 033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM- 80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS- 9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and A molding integrating sphere with holder base. This sphere is more round and the test result is more accruacy than the traditional integrating sphere. Measures: • Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test • Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF • Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic • LED Light Decay Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time. Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82 High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufactory or General Test Lab): High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE- 19IN). You can download the detail PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure Specification: • Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm • Sample Scanning Steps: ±0.1nm • Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp) • Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3% • Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3) • Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5% • Stray light: <0.015%(600nm) and <0.03%(435nm) • Integration Time: 0.1~10,000ms • It can measure the temperatures inside and outside of integrating sphere • Flux testing method: spectrum, photometric and spectrum with photometric revision • The system includes the auxiliary lamp device and the software includes self- absorption function • It can measure the temperatures inside and outside of integrating sphere • Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft) • The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF. Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab): Scientific Grade CCD Spectroradiometer (LMS-9500C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050C), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure Specification: • CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector • Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm • Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp) • Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2% • Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3) • Photometric linear Accuracy: ±0.2% • Stray light: <0.015%(600nm) and <0.03% (435nm) • Integration time: 0.1ms-60s • It can measure the temperatures inside and outside of integrating sphere • Flux testing method: spectrum, photometric and spectrum with photometric revision • The system includes the auxiliary lamp device and the software includes self- absorption function • It can measure the temperatures inside and outside of integrating sphere • Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft) • The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/25/23 7:06 GMT
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for single LED and LED luminaires' photometric, colorimetric and electrical measurement. The measured data meets the requirements of CIE 177, CIE84, CIE-13.3, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IES LM-79-19, Optical-Engineering-49-3-033602, IESNA LM-63-2, ANSI- C78.377 and GB standards The Sphere System Configuration: CCD Spectroradiometer (LMS-7000), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2008R), DC Power Source (DC-S Series), AC Power Source (LSP-500VAS), Integrating Sphere (IS-1.5MA-CASE and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W) Measurement: • Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI (Ra, R1 to R15), Spectrum Test, TM30 (Rf, Rg), CQS • Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, PAR, PPF • Electrical: Voltage, Current, Power, Power Factor, Harmonic (Optional) Specification: • Spectral Range Wavelength: 350nm~950nm(LMS-700VIS) (200~1050nm is optional) • Spectral Wavelength Accuracy: ±0.5nm Wavelength Reproducibility: ±0.5nm • Sample Scanning Steps: ±0.1nm • Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.003 (under Standard A Lamp) • Correlated Color Temperature CCT: 1,500K~25,000K. CCT Accuracy: ±0.5% • Color Rendering Index Range: 0~100.0, Accuracy: ± (0.3%rd±0.3) • Photometric linear: ±0.5% • Stray light: <0.015% (600nm) and <0.03% (435nm) • The system includes the auxiliary lamp device and the software includes self- absorption function • Connect with PC via USB cable. The English version software can be run in Win7, Win8 and Win10, Win11 (The driver was Certificated by Microsoft) Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/25/23 7:00 GMT
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1890BCCD/LSG-1800ACCD goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source. The LSG-1890BCCD/LSG-1800ACCD can do the spatial CCT test and the intensity distribution test. It is for industrial laboratory photometric data measurement of luminaires such as LED luminaires, LED Plant Lighting, HID luminaires, fluorescent lamps and so on. Standard: Full meet the EN13032-1 clause 6.1.1.3 goniophotometer type 1, COMMISSION DELEGATED REGULATION (EU) 2019/2015, CIE-70, CIE-121, IES LM-79, IES LM-75, IES LM-80 and ect. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, CCT, CRI, Color Temperature Distribution, Spectrum, (x, y)/(u, v), PAR, PPF, PPFD 3D distribution test and etc. Specification: • LSG-1890BCCD/LSG-1800ACCD Goniospectroradiometer=LSG-1890B/LSG-1800A Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System • The goniophotometer can do the B-β test with two pillars and the C-γ test with single pillar & multi-function jigs • Test Max Luminaires size and weight: LSG-1890BCCD is 2000mm/60kg and LSG- 1800ACCD is 1600mm/50kg • The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the tested luminaries rotates around itself with an angle of (C)±180°(or 0- 360°) • Luminosity Testing Range: Illuminance 0.01lx~99,999lx; Light Intensity 1.0cd~10^7cd (detector) • Angle accuracy: LSG-1890BCCD is 0.1°, LSG-1800ACCD is 0.2° • Work with high accuracy and quick CCD Spectroradiometer to measure spatial color parameters • Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A lamp) • Spectral Range Wavelength: 350nm ~800nm; Accuracy of wavelength: ±0.5nm • The Hardware and Software can do the PAR, PPF and PPFD 3D distribution test, which can export IES/LDT files • Photometry Accuracy: CIE Class A (Class L is option) • Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1% • English version software can run in Win7, Win8 or Win10, Win11 • LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be transferred by other illumination and luminaire design software such as DiaLux Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/25/23 6:56 GMT
LM-79 Moving Detector Type C Goniophotometer
What is type C goniophotometer definition? LSG-6000 Moving Detector Goniophotometer (Mirror Type C) was manufactured by LISUN completely meets LM-79-19, IES LM-80-08, COMMISSION DELEGATED REGULATION (EU) 2019/2015, CIE-121, CIE S025, SASO 2902, IS16106 and EN13032-1 clause 6.1.1.3 type 4 requirements. LSG-6000 is the latest upgraded product of LSG- 5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. What is the use of goniophotometer? LSG-6000 gonio photometer manufacturer is LISUN, it can measure all types of lighting sources, LED, Plant Lighting or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires. Measurement: Luminous Intensity Data, Photometric Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc. Features: • The near field detector moves together with the big mirror in a line. The big mirror and the far field detector move synchronously. • The burning position of the lumainares will be kept without moving at all, and the detector will always sense the light directly from the luminares. • The rotary motor is from Japan MITSUBISHI MOTORS and the angle decode system is from Germany. They help the goniophotometer rotating smoothly with high accuracy. It is very stable when start and stop. • The working principles are according to IESNA and CIE. The LSG-6000 completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996 standards. • Special collimation device with cross laser line help you installing the position of the luminaires under test conveniently and accurately. Specifications: • The luminaire under test rotates around the mirror with an angle of (γ) vertical axis ±180° (or 0-360°) and the luminaire rotates around itself with an angle of (C) horizontal axis ±180° (or 0-360° ). • The accuracy of angle: 0.05°, Resolution of angle: 0.001° • Accuracy of Goniophotometry detector: Constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L • LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illumination and luminaire design software such as DiaLux. • Connect the goniophotometer to PC via USB cable. English version software can run on Win7, Win8 or Win10, Win11 • LSG-6000 can be used together with a CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system "Goniospectroradiometer (LSG-6000CCD)". LSG-6000CCD Goniospectroradiometer = LSG-6000 Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System. Please click to download the LSG-6000CCD Brochure • The LSG-6000CCD software and hardware support the plant lighting PAR, PPF and PPFD spatial distribution test , and it can export IES/LDT files How does Mirror Goniophotometer work? Goniophotometer adopts the measuring principle of fixed detector and rotating lamp method. The measuring lamp is installed on a two-dimensional rotating worktable, and the luminous center of the lamp coincides with the rotating center of the rotating worktable through the laser beam of the laser sight. Minimum Order: 1 bags Contact:
Phone: Fax: Email: LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai 201802 China 6/20/23 11:36 GMT
Wire Harness
This is Wiring Harness supplier nancy from Guangdong R-Yangling Electronic Technology Co., LTD which was established in 2019. Our company is committed to R&D, design and production of wiring harnesses, connectors, capacitors, ics, custom wiring harnesses. We mainly supply Industry/ Auto/ Medical wiring harness and support customed non-standard cables. YL Please contact Nancy to know more about information. Email:105@hccables.com Our company webstie: www.hccables.com Contact:
Phone: Fax: Email: Guangdong R-Yangling Electronics Technology Co.,Lt
Unit 1906, Office Building, Zone 4, Diwang Plaza, 303 Changqing South Road,, ChangAn Town, Dongguan, DongGuan 52388 China 6/20/23 8:31 GMT
LHL X100-7 700g
Guangdong, China Brand Name: LUBE Application: Industrial Lubricant, Lubricating Type: Greases Specification:< , br>700 General Composition: BASE Oil Model Number: LHL-X100-7 Product name: LUBE Grease Model: LHL-X100-7 Keywords: Gre , ase Feature: multi-purpose OEM: Availa , ble Size: 700cc MOQ: 1 Piece Delivery: 1-5 days Port: Shenzhne Minimum Order: 1 bags Contact:
Phone: Fax: Email: Guangdong Juguang Heng automation equipment Co., L
Third floor, Workshop no.5, Yuangang Street, Xingang Road, Xinan Community, Changan, Dongguan city guangdong China 6/19/23 8:45 GMT
NON ADHESIVE PVC TAPE
Egret so-called non adhesive pvc tape is used a lot for wrapping the air conditioner pipe, so it is also called PVC pipe wrapping tape. The base material is pure PVC resin, no need of coating glue, and it is self-adhering. Moreover, the pvc material has different thicknesses, from 90 microns to 200 microns. In particular, the material has very good elongation rate, high tensile strength. Plus, it is easy to tear by hand, and excellent self-adhering properties. Furthermore, it has outstanding softness and conformity, elasticity features. As a result, pvc non adhesive tape is very suitable for wrapping the household air condition pipe. Consequently, the tape can protect the pipe from corrosion and damage. Features of Non Adhesive PVC Tape 4.8 mil (120 micron) smooth PVC backing with high tensile strength Without coating any adhesive Different color is available as per your requirement Easy for hand-tear, easy-used by workers on site Excellent conformity to uneven surface applications Excellent resistance to moisture and vapor, corrosion Easily wrapping on the tubes or pipes There are many industrial tape manufacturers, but we are one of the best choices for you. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Changzhou Egret Manufacturing Co., Ltd
No.4, Tongshun Rd, Henglin Town, Changzhou 213101, China henglin China 6/19/23 8:44 GMT
NBR FOAM TAPE
NBR foam tape stands for nitrile-butadiene rubber foam tape, also called as PVC foam tape. Thermoplastic elastomer is also called artificial rubber or synthetic rubber. Its products not only have the high elasticity, aging resistance, oil resistance of traditional cross-linked vulcanized rubber, but also have the characteristics of common plastic processing convenience, processing mode wide. It can be produced by injection molding, extrusion, blow molding and other processing methods. Moreover, all products meet the RoHS environmental requirements. Furthermore, we can either provide jumbo rolls, or die cutting pieces. The width can be from 10mm to 1600mm, the length can be from 100mm to 2000mm. Features of NBR Foam Tape 2mm high-density closed-cell NBR foam as carrier Coated with special formula of very high tack adhesive Laminated with yellow paper easy release liner Excellent properties of high elasticity Outstanding aging resistance, oil resistance Good high temperature resistance Great air sealing, moisture sealing Outstanding conformity to uneven surfaces If you need any kinds of non adhesive pvc tape, please contact us, as a professional adhesive tape factory, HUASHANG is willing to offer you high quality products. Contact:
Phone: Fax: Email: Changzhou Egret Manufacturing Co., Ltd
No.4, Tongshun Rd, Henglin Town, Changzhou 213101, China henglin China 6/19/23 7:35 GMT
High resolution lcd display 640x480 with Resistive touch pane
Part Number: TST057VGGH-02P Display Mode:5.7''/TFT/IPS/Transmissive/Normally White Resolution: 640xRGBx480 Active Area: 115.2x86.4 mm View Direction: 6 o'clock Interface: RGB24-bit Surface Luminance: 700nits Operating Temperature: -20℃~70℃ Storage Temperature: -30℃~80℃ Minimum Order: 100 Contact:
Phone: Fax: Email: Dongguan Team Source Display Technology Co., Ltd.
CN Factory Address: 2F, Bld 1, Lihao International Technology Park,Zhutang,Fenggang,Dongguan,China.5 DONG GUAN 523681 China 6/19/23 3:47 GMT
LW34-12 10KV outdoor SF6 circuit breaker
LW34-12 10KV outdoor SF6 circuit breaker Product Description LW34-12 10KV outdoor high voltage SF6 circuit breaker is a new outdoor high- voltage electrical arcing and SF6 gas as insulating medium. The operating mechanism points manual storage spring mechanism, motor energy storage spring mechanism, DC electromagnetic actuator three, all kinds of fish breaker actuator perfect combination of body as a whole. This product compared to other fish 10kV class outdoor circuit breakers, has a simple structure, high arcing and insulation performance, small operating power, high ratings, long life and no maintenance cycle and other significant advantages. Use of this product will not only reduce the area. Reduce project cost and eliminate the risk of fire, and can greatly improve the reliability of the power system. Technical parameter Rated voltage (kV) Rated current (A) Rated short-circuit breaking current (kA) Rated short-circuit current (kA) Rated peak withstand current (kA) Rated short time withstand current (KA) Rated short duration (S) Rated short-circuit current breaking times Weight (kg) 10 400 630 6.3 8 12.5 16 20 16 20 6.3 8 12.5 4 30 130 Contact:
Phone: Fax: Email: Bokong Electric Co., Ltd
191, Wei shiliu Road, Yueqing City Economic Development, Zhejiang Province, China Wenzhou 325604 China SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)