Import-Export Bulletin Board Post an Offer to Sell

New here? Please subscribe
to post trade leads. It's FREE!

Electronics & Electrical


Home > Offers to Sell > Electronics & Electrical

Browse leads by category:
    
    
    
    
    
    
 

Summary of 8/17/26 8:22 GMT:>> Show Compact View
6/29/23 1:47 GMT
Hydrargyrum Medium ARC Lodide Lamp

SUNNY XIAO Sunlite's full-spectrum sunlight simulation system, hydrargyrum medium arc iodide, can perfectly mimic natural sunlight, providing uniform and reliable sunlight radiation simulation, and is widely used in environmental simulation tests of aerospace equipment, automobiles and rail transit vehicles. SUNNYXIAO FILMLITE series lighting for high-speed video, which is of high power, high brightness, high CRI, and long irradiation distance, is catered for scenarios such as high-speed imaging lighting for a collision of large vehicles and aerobats. Advantages SUNLITE 2000 HQI & Q2000 Ballast Patented light reflection system; Patented timing circuit technology; Excellent protection treatment; Superheat dissipation structure; Four power modules are integrated into one Ballast. FILMLITE 4000 HMI & S4000 Ballast Uniform light spot and high light efficiency; At least 20% more durable without any flicker; 30% lighter in weight; Superheat dissipation structure; Compensation of cable loss (CCL); Ingress protection rating of IP23; Polygonal parabolic reflector technology; Up to 4560 3D mesh mirrors; Ballast self-adapting for 4,000W and 2,500W HMI lamps. If you want to know more kinds of led soft light panel, please visit our website.

Contact:
Phone:
Fax:
Email:
sunnyxiao
0755-23008852
0755-23008852
Send Inquiry
ShenZhen Sunny Xiao Technology Co., Ltd.
Room 1505-1506, Block B, Rongchao Binhai Building, No.2021-1 Haixiu Road, Bao'an CBD,Shenzhen 518133
Shenzhen 518133
China
6/29/23 1:46 GMT
Soft LED Light Panel

LED Light Panel for Sale The LED-based Caster Series of SUNNYXIAO portable LED soft light panel consists of 4 kinds. The Caster soft led light panel products are compact and portable LED light panel that utilizes an advanced optical design and a LED arrangement that provides an efficient solution for LED lighting at an attractive price level. As a leading led light panel china manufacturer in China, SUNNYXIAO develops an APP for remote control and offers versatility when lighting tight spots in small and medium-sized studios. Intensity, color temperature and ± green can be independently controlled. Hard Light VS Soft Light Photography Photography is a matter of light, and that light has the quality of being either “hard” or “soft.” Soft lighting is a type of led soft panel light with little hard shadows that are bright yet balanced. In soft lighting, the transition between the portable soft led panel and the shadows is more of a gradient and much smoother. When your subject is bathed in soft light, there will be barely any no shadows on their face. And even if there is a shadow, it is not as dark as they are in shadows cast in the hard light. Soft led light panel in film and television lighting belongs to soft light. In contrast, hard light is light that contains very sharp immediate transitions from highlights to shadows. The edges of the shadows will be very defined and “hard.” There will also serve as a stark difference between the darkest and lightest areas of the image. It also reveals the lines and surface details of the subject. Flash and spotlight are all hard light.

Contact:
Phone:
Fax:
Email:
sunnyxiao
0755-23008852
0755-23008852
Send Inquiry
ShenZhen Sunny Xiao Technology Co., Ltd.
Room 1505-1506, Block B, Rongchao Binhai Building, No.2021-1 Haixiu Road, Bao'an CBD,Shenzhen 518133
Shenzhen 518133
China
6/28/23 10:24 GMT
3528 Series Flexible LED Strip Light 12v To 24V 2400 To 7000K

Description of LED Strip 3528 Series From the perspective of market demand, LED light strips are more and more widely embedded in various fields. In recent years, with the increasing demand in interior decoration, advertising production, architectural lighting and other fields, the market demand for LED strips has also begun to show explosive growth. At the same time, the function and form of LED light strips are also constantly upgraded, and the application level is constantly expanding. 1. High brightness: Compared with traditional lighting products, LED light strips have higher brightness and can provide better lighting effects under the same power. 2. Low power consumption: Under the same lighting requirements, LED light strips consume relatively less power, saving electricity costs. 3. Long service life: Compared with traditional lamps, LED light strips have a longer service life. In general, the frequency of replacing lamps and maintenance costs can be reduced. 4. Rich colors: Compared with traditional lighting products, LED light strips can provide a variety of color options according to needs, and can also provide different brightness adjustments according to needs. These functions show that the LED light strip can meet the needs of various lighting effects. 5. Environmental protection and energy saving: In the manufacturing process of LED light strips, there is no need to use a variety of harmful substances, and at the same time, the power of LED light tubes can be converted into light energy, reducing environmental pollution.

Contact:
Phone:
Fax:
Email:
Mrs. Sun
86-132-18172900
86-132-18172900
Send Inquiry
Suzhou Dengmihui Lighting Technology Co., Ltd.
Floor 4, Building B, Baodai Science and Technology Park, No. 988, Wusong Road, Wuzhong District, Suzhou
suzhou 215000
China
6/28/23 6:57 GMT
X Ku Band WR75 BJ120 9.85 to 15.0GHz RF Waveguide to Coaxial Adapters

Model Number:UIYWTCWR75E984T15SF Frequency Range:9.84~15.0GHz Insertion Loss:0.3dB VSWR:1.25 Connector Type(Waveguide):WR75(BJ120) Connector Type(Coaxial):SMA-F CW Power:50W Peak Power:1KW Temperature:-55~+85°C

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Kelly Hu
86075583748888
86-755-25999959
Send Inquiry
UIY Inc.
No. 8, Lane 1, Xintun East Zone, Longgang District
Shenzhen 518172
China
6/28/23 4:00 GMT
X Ku Band 11.9 to 18.0GHz WR62 BJ140 RF Waveguide to Coaxial Adapters

Model Number:UIYWTCWR62E119T18SF Frequency Range:11.9~18.0GHz Insertion Loss:0.3dB VSWR:1.25 Connector Type(Waveguide):WR62(BJ140) Connector Type(Coaxial):SMA-F CW Power:50W Peak Power:1KW Temperature:-55~+85°C

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Kelly Hu
86075583748888
86-755-25999959
Send Inquiry
UIY Inc.
No. 8, Lane 1, Xintun East Zone, Longgang District
Shenzhen 518172
China
6/25/23 7:21 GMT
Salt Spray Test Chamber

Salt Spray Test Chamber Salt Fog Test ASTM B117 Salt Spray ChamberSalt Spray Test Chamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. The salt fog test chamber meets the following standards: IEC60068-2-11 (GB/T2423.17), GB/T10125, GB/T1771, ISO9227, ASTM-B117, GB/T2423-18, QBT3826, QBT3827, IEC 60068-2-52, ASTM-B368, MIL-STD- 202, EIA-364-26, GJB150, DIN50021-75, ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc. Specifications: • A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow. • Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement. • The Salt Spray Chamber Working room temperature range:RT+5ºC~50ºC (The setting value cannot be lower than the current ambient temperature); Saturated barrel temperature: +40°C~+63°C; • Brine temperature: preheated by laboratory temperature; Temperature uniformity: ≤ ±2°C; Temperature fluctuation: ≤ ±1°C; • The Salt Spray Test time: 0-99,999m (adjustable); Settlement: 1-2ml/80cm²/h; • The Salt Spray Test Chamber Spray method: NSS (neutral) test, AASS (acidic) test, CASS (copper acceleration) test, custom test, programmable test, each test can choose continuous spray or intermittent spray (according to industry standards). The ratio of each test solution has a corresponding explanation in the test setting interface. • Sample holder: at an angle of 15 to 30 degrees from the vertical surface (with sample standard placed). Other irregular samples are recommended to remain tilted. The V-groove has a single weighing capacity of 3KG, and the O- bar has a single bearing capacity of 5KG. It is strictly forbidden to place samples under heavy weight. How do you do a salt spray test? 1. First power on the salt spray test chamber (plug in) 2. Press the red power switch panel from left to right, respectively: the low water level A light is on, the low salt water B light is on, and the low water level C light is on. 3. Pour distilled water directly into the test chamber, wait until the water level A indicator light off, and stop adding water. […more…] How Long does a Salt Spray Test Take? The Salt Spray Test Chamber is an environmental test equipment that evaluates the corrosion resistance of products or metal materials by artificially simulating salt spray environmental conditions. The chloride concentration in the salt spray environment can be several or tens of times the salt spray content of the general natural environment, which greatly increases the corrosion rate. The salt spray testing of the product can greatly shorten the time to obtain the result. For example, if a product is tested in a natural exposure environment, it may take 1 year for its corrosion, while a test in salt spray test chamber may take as long as 24 hours to obtain similar results. How to use a salt spray test chamber to determine the corrosion resistance of LED lamps? Salt spray test is a kind of environmental reliability test, mainly used to test the corrosion resistance of metal materials of lamps. In order to verify whether the metal parts on the product will corrode when exposed to the atmosphere or other environments, the product can be placed in the use environment for a long enough time, such as a product life cycle. This is time- consuming and labor-intensive. In practice, it is rarely used, so a convenient method is needed to evaluate the corrosion resistance of the product.

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:19 GMT
Dustproof Testing Machine for IP5X and IP6X

SC-015 Dust-proof Test Chamber (Sand Dust Chamber) is applied to physical and other related performance tests for electronic and electrical products, lamps, electrical cabinets, electrical components, automobiles, motorcycles and their parts and other products under simulated dust climate conditions. After the measurement, it is judged whether the performance of the product meets the requirements through verification, so as to facilitate the design, improvement, verification and factory inspection of the product. Comply meets IEC60529:1989 +A1:1999 +A2: 2013 ,IEC60598-1, GB2423.37-89 (Test L: dust test methods), GB4208, GB/T 4942.2-93(protective casing grade of low-voltage apparatus), GB7000.1 9.2.1, 9.2.2 and Figure 6, DIN40050 and IP5K0. The dust test chamber is applicable to the IP5X and IP6X dustproof test of the products. Specifications: • Temperature range: RT+10~50ºC • Standard wire warp of metal net: 50um; Standard spacing between wires: 75um • Test dust: dry talc powder; Talc powder dosage: 2~4kg/m; Dust reduction method: free dust reduction • Total test time: 0~999H (adjustable); vibration time: 0~999H (adjustable); timing accuracy: ±1 second • Vacuum: 0~10Kpa (adjustable); Pumping speed: 0~4800L/H (adjustable) • Power supply of test samples: single-phase 220V/50Hz or 100V/60Hz • Safety protection function: leakage protection, short circuit protection • The shell is made of domestic high-quality steel plate, and the surface is sprayed with paint, which is beautiful and durable. • The inner box, sample rack, etc. are made of stainless steel plates to ensure that they will not rust for a long time. • There is a transparent observation window (toughened glass material) on the door, and an LED lighting lamp is installed in the box to facilitate the observation of the internal test situation. • There is a device for replacing dust at the bottom of the device, which can easily 100% replace the used dust. • A special device is installed to ensure that the dust does not stick to the wall and condense. The working time of the device is adjustable, and it can work automatically and alternately. • There is a suction pipe in the box, which can complete the vacuum action on the sample (require the sample to reserve the suction hole position). • Dust chamber testing control system: 7-inch touch screen + Panasonic PLC. The dust blower, dust vibration and total test time can be controlled separately. This controller has the following various arbitrary setting control functions: 1. Dust blowing time (stop, blowing): can arbitrarily choose any of continuous and periodic dust blowing time to setting; 2. Vibration time: vibration and stop vibration time are automatically alternated; 3. Preset test time: the maximum test time is 99 hours and 59 minutes; • Heating system: The circulating air duct is equipped with a heater to heat the dust to avoid dust condensation. The heat of the muffler mica sheet heating ring is safe and stable. • Vacuum system: equipped with vacuum pump, vacuum pressure, air filtration, flow meter, pressure regulating triplet, connecting pipe.

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:17 GMT
Waterproof Test Machine for IPX1 to IPX8

JL-X waterproof test machine is according to IEC60529:1989 +A1:1999 +A2:2013 Degrees of protection provided by enclosures(IP Code), IEC60598, IEC60335 and IEC 60034-5, GB/T-2423.2, GB4208, GB7000.1. The JL-X includes the following test grades: IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7 and IPX8 (Refer to page 51 of IEC60529). It is widely used in the authentication test organization for the products such as electrical & electronic products, LED luminaires as well as in the relevant quality control department for the waterproof detection of the enclosures protection grades. The whole JL-X waterproof test system includes: • Drip Box (JL-12): The drip box is for IPX1 and IPX2 drip test. The drip box size is 800x800x45mm (LxWxH). The diameter of drip hole is 0.4mm. The distance between drip holes is 20mm. The sample can be over 150kg. • Swing Pipe Water Spray Test Equipment (JL-34): It is for IPX3 and IPX4 waterproof test. The semi-diameter of swing pipe is 1meter (Any other size is also available). The inside diameter of the swing pipe is 15mm. The sample rotating table diameter is 1000mm (Or other size according to the diameter of the swing pipe), and the height is adjustable. The rotation speed is 1~5rpm which controlled by PLC panel. • Waterproof Jet Test Device (JL-56): With water supply device size is 1000x1000x600mm, the nozzle diameter is ф6.3mm (IPX5 waterproof test ) and ф12.5mm (IPX6 waterproof test). The water speed is 12.5 ±0.626L/min for IPX55 and 100 ±5L/min for IPX6 • Immersion tank Waterproof test Device (JL-7): It is for IPX7 waterproof test. The water tank size is 1000x1000x1200mm (Other size can be designed according to your request). It can test samples up to 120kg. • Immersion tank Waterproof test Device (JL-8): It is for IPX8 test. It can simulate a water depth of 0~50m. The water immersion tank diameter is 600mm and the height is 1200mm. The compressive stress is 10 atmospheres or design according to customer's request.

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:15 GMT
Lamp Start, Run-up time and Flicker Test

LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer - Flicker Tester is equipped with Class A fast photometric probe, so the sampling speed is up to 100kHz. It fully meets the requirement of BASIC, Energy Star V2.1, IEC TR 61547-1:2020 IEC-Pst, CA CEC, ASSIST, CIE TN006-2016 CIE SVM, IEEE Std 1789 standards, etc. It is professional for flicker test of LED lights and lamps, energy-saving lamps, etc. According to EU directives 1194/2012, 2009/125 / EC, SASO2902, COMMISSION DELEGATED REGULATION (EU) 2019/2015, COMMISSION REGULATION (EU) 2019/2020 and IEC60969 "Self-ballasted Lamps for General Lighting Services-Performance Requirements" and other requirements. The LSRF-3 can connects with PC via USB cable. The English version software can be run in Win7, Win8 and Win10, Win11 (The driver was Certificated by Microsoft) Lamp Flicker test interface needs to work with LISUN Integrating Sphere, DC Power Source and Standard Light Source, it also can be added in LISUN LPCE-2 /LPCE-3 Integrating Sphere System or LSG-6000/LSG-1890B/LSG-1800A Goniophotometer or LSG-6000CCD/LSG-1890BCCD/LSG-1800ACCD Goniospectroradiometer.

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:13 GMT
High Precision Rotation Luminaire Goniophotometer

What is goniophotometer definition? LSG-1890B/LSG-1800A goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for rotating the light source. The LSG-1890B/LSG-1800A uses a constant temperature detector, Japanese motor and German precision angle coder which keep the test results with high accuracy. It is for industrial laboratory photometric data measurement of all kinds of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on. Standard: Full meet the EN13032-1 clause 6.1.1.3 goniophotometer type 1, COMMISSION DELEGATED REGULATION (EU) 2019/2015, CIE-70, CIE-121, IES LM-79, IES LM-75, IES LM-80 and ect. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency(Option),Luminance Distribution,Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc. Specification: • The goniophotometric instrument can do the B-β test with two pillars and the C-γ test with single pillar & multi-function jigs • Test Max Luminaires size and weight: LSG-1890B is 2000mm/60kg and LSG-1800A is 1600mm/50kg • The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the tested luminaries rotates around itself with an angle of (C)±180°(or 0- 360°) • Luminosity Testing Range: Illuminance 0.01lx~99,999lx; Light Intensity 1.0cd~10^7cd (detector) • Angle accuracy: LSG-1890B is 0.1°, LSG-1800A is 0.2° • Photometry Accuracy: CIE Class A (Class L is option) • Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1% • English version software can run in Win7, Win8 or Win10, Win11 • LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be transferred by other illumination and luminaire design software such as DiaLux. What are the types of goniophotometer? The types of Goniophotometers can be basically divided into Type A, Type B and Type C. For a detailed description, please refer to the 1987 edition of CIE 70. The difference between them lies in the way the lighting equipment rotates during the measurement and the photometric data obtained during this measurement. How does goniophotometer measures? Goniophotometer is a device used to measure the light distribution performance of lamps. Goniophotometer measures the spatial light intensity distribution of lamps or light sources, total luminous flux and lamp efficiency and other parameters. Goniophotometer need to work in larger darkroom. Use low-reflectivity materials in the room to avoid reflected light from entering the probe. Depending on the arrangement of the measuring light path, two measurement schemes can be used to measure the luminous flux: the illuminance integral method and the luminous intensity integral method.

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:11 GMT
EMI Receiver System

EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPR15:2018, CISPR16-1, GB17743, FCC, EN55015 and EN55022. System Configurations: • EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K- 1GHz), LISN-A Artificial Network Power (16A with RS-232 communicate), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers and cables. • EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN-A Artificial Network Power (5A), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers, Attenuator and cables. • EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN-A Artificial Network Power (5A), 3pcs Isolation Transformers, Attenuator and cables. Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers: • LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Source for EUT • LISUN SDR-2000B Magnetic Shielding Cabinet for the EMI Receiver System • LISUN VVLA-30M Three Loop Antenna to test 9k-30MHz Radiation • LISUN AB-CLP Absorbing Clamp to test the Home Applications & motor tools Specification: • Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA) • Frequency stability: 1×10^-6 • Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz • Test Tolerance: ±2 dB • Measure and Detection method: PK, QP and AV • Measure range from 20dBμV to 140dBμV • Frequency scanning step length: 20Hz~2MHz • Sweep bandwidth: 200Hz; 9kHz; 120kHz • Connect PC via USB cable and software can run on Win7, Win8 and Win10, Win11 What is EMI receiver? Electromagnetic Interference (EMI receiver) is electronic noise that interferes with cable signals and reduces signal integrity. EMI Receiver is usually generated by electromagnetic radiation sources such as motors and machines. EMI Receiver (Electromagnetic Interference) has two types: conducted interference and radiated interference. Conducted interference refers to the coupling (interference) of signals on one electrical network to another electrical network through a conductive medium. Radiated interference refers to the interference source coupling (interference) its signal to another electrical network through space. How to test EMI Interference? Electromagnetic disturbance that degrades the performance of electrical equipment or electronic device, works abnormally or fails. It can be divided into conducted interference test and radiated interference test. LISUN EMI-9KB is an automatic EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. It can do both conducted interference test and radiated interference test. What's the difference between EMI and EMS? EMC (Electro Magnetic Compatibility) literally translates to "electromagnetic compatibility". EMI (Electromagnetic Interference) "Electromagnetic Interference" can be understood as attack type. There are two types of EMI, conducted interference and radiated interference. EMS (Electro Magnetic Susceptibility) literally translates to "electromagnetic sensitivity", which we can understand as defensive type, which means the ease of performance degradation due to electromagnetic energy. Noted: According to latest CISPR15:2018 standard, you need to use CDNE-M316 (Coupling/Decoupling Network for Emission) to instead the CDN. The CDNE-M316 worked with EMI receiver system is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30M-300mHz

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:10 GMT
High Voltage Lightning Surge Generator

Product Description The SG61000-5 fully automatic surge generator (also called lightning surge immunity test, combination wave generator, surge current generator/surge voltage generator, combined surge voltage and current generator) . How does a surge generator work? The SG61000-5 surge generator provides a common basis for evaluating the resistance of power cords and internal connectors of different equipment to high energy transient interference caused by natural lightning surge induction and large capacity load switching. It fully meets the IEC 61000-4-5, EN61000-4- 5 and GB/T17626.5 standards.

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:07 GMT
High Precision Spectroradiometer Integrating Sphere System

LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED's quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3- 033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM- 80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS- 9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and A molding integrating sphere with holder base. This sphere is more round and the test result is more accruacy than the traditional integrating sphere. Measures: • Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test • Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF • Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic • LED Light Decay Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time. Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82 High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufactory or General Test Lab): High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE- 19IN). You can download the detail PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure Specification: • Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm • Sample Scanning Steps: ±0.1nm • Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp) • Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3% • Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3) • Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5% • Stray light: <0.015%(600nm) and <0.03%(435nm) • Integration Time: 0.1~10,000ms • It can measure the temperatures inside and outside of integrating sphere • Flux testing method: spectrum, photometric and spectrum with photometric revision • The system includes the auxiliary lamp device and the software includes self- absorption function • It can measure the temperatures inside and outside of integrating sphere • Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft) • The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF. Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab): Scientific Grade CCD Spectroradiometer (LMS-9500C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050C), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure Specification: • CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector • Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm • Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp) • Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2% • Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3) • Photometric linear Accuracy: ±0.2% • Stray light: <0.015%(600nm) and <0.03% (435nm) • Integration time: 0.1ms-60s • It can measure the temperatures inside and outside of integrating sphere • Flux testing method: spectrum, photometric and spectrum with photometric revision • The system includes the auxiliary lamp device and the software includes self- absorption function • It can measure the temperatures inside and outside of integrating sphere • Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft) • The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:06 GMT
CCD Spectroradiometer Integrating Sphere Compact System

LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for single LED and LED luminaires' photometric, colorimetric and electrical measurement. The measured data meets the requirements of CIE 177, CIE84, CIE-13.3, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IES LM-79-19, Optical-Engineering-49-3-033602, IESNA LM-63-2, ANSI- C78.377 and GB standards The Sphere System Configuration: CCD Spectroradiometer (LMS-7000), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2008R), DC Power Source (DC-S Series), AC Power Source (LSP-500VAS), Integrating Sphere (IS-1.5MA-CASE and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W) Measurement: • Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI (Ra, R1 to R15), Spectrum Test, TM30 (Rf, Rg), CQS • Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, PAR, PPF • Electrical: Voltage, Current, Power, Power Factor, Harmonic (Optional) Specification: • Spectral Range Wavelength: 350nm~950nm(LMS-700VIS) (200~1050nm is optional) • Spectral Wavelength Accuracy: ±0.5nm Wavelength Reproducibility: ±0.5nm • Sample Scanning Steps: ±0.1nm • Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.003 (under Standard A Lamp) • Correlated Color Temperature CCT: 1,500K~25,000K. CCT Accuracy: ±0.5% • Color Rendering Index Range: 0~100.0, Accuracy: ± (0.3%rd±0.3) • Photometric linear: ±0.5% • Stray light: <0.015% (600nm) and <0.03% (435nm) • The system includes the auxiliary lamp device and the software includes self- absorption function • Connect with PC via USB cable. The English version software can be run in Win7, Win8 and Win10, Win11 (The driver was Certificated by Microsoft)

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China
6/25/23 7:00 GMT
High Precision Rotation Luminaire Goniospectroradiometer

LSG-1890BCCD/LSG-1800ACCD goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source. The LSG-1890BCCD/LSG-1800ACCD can do the spatial CCT test and the intensity distribution test. It is for industrial laboratory photometric data measurement of luminaires such as LED luminaires, LED Plant Lighting, HID luminaires, fluorescent lamps and so on. Standard: Full meet the EN13032-1 clause 6.1.1.3 goniophotometer type 1, COMMISSION DELEGATED REGULATION (EU) 2019/2015, CIE-70, CIE-121, IES LM-79, IES LM-75, IES LM-80 and ect. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, CCT, CRI, Color Temperature Distribution, Spectrum, (x, y)/(u, v), PAR, PPF, PPFD 3D distribution test and etc. Specification: • LSG-1890BCCD/LSG-1800ACCD Goniospectroradiometer=LSG-1890B/LSG-1800A Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System • The goniophotometer can do the B-β test with two pillars and the C-γ test with single pillar & multi-function jigs • Test Max Luminaires size and weight: LSG-1890BCCD is 2000mm/60kg and LSG- 1800ACCD is 1600mm/50kg • The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the tested luminaries rotates around itself with an angle of (C)±180°(or 0- 360°) • Luminosity Testing Range: Illuminance 0.01lx~99,999lx; Light Intensity 1.0cd~10^7cd (detector) • Angle accuracy: LSG-1890BCCD is 0.1°, LSG-1800ACCD is 0.2° • Work with high accuracy and quick CCD Spectroradiometer to measure spatial color parameters • Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A lamp) • Spectral Range Wavelength: 350nm ~800nm; Accuracy of wavelength: ±0.5nm • The Hardware and Software can do the PAR, PPF and PPFD 3D distribution test, which can export IES/LDT files • Photometry Accuracy: CIE Class A (Class L is option) • Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1% • English version software can run in Win7, Win8 or Win10, Win11 • LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be transferred by other illumination and luminaire design software such as DiaLux

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Rachel He
8615317383997
+86(21)51083342  
Send Inquiry
LISUN INSTRUMENTS LIMITED
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road
Shanghai 201802
China


SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)
Result Page:   << Previous   |   283  |   284  |   285  |   286  |   287  |   288  |   289  |   290  |   291  |   292  |   293  |   Next >>

Post an Offer to Sell
Home - Offers to Buy - Business Opportunities - Company Profiles

© 1996-2026 IMEXBB.com. All rights reserved.

IMEXBB.com