Offers to SellHome > Offers to Sell
2/2/24 6:40 GMT
Super Body Shape Body Slimming Face Lifting Machine with RF Roller Factory
Model:iShape II Super Body Shape Body Slimming face lifting machine with RF Roller factory price Beauty Equipments Applications: 1) Fat and Cellulite Reduction 2) Body Contouring 3) Facial Lifting and Body Tightening 4) Skin Texture improvement 5) Lips and eye contours and wrinkle removal 6) Mechanical Massage Working Principle: Technology 1: Cavitation 40KHz Cavitation technology in itself means that the ultrasound causes the fat cells to vibrate so fast (high frequency) so vacuum bubbles are formed in the cell. As a consequence, the outer casing of the fat cells (the membrane) is "blown out" and the fat ends outside the cells. Outside of the membrane, the fat can be broken down to rapidly accessible energy, which is then taken up in the blood or transported by lymph nodes, after which they are either burned or stored in other fat cells elsewhere in the body. Technology 2: 940nm infrared light Infrared light (IR) has a direct and very positive effect on muscles and joints. IR increases the oxygenation in the cells and gives a warming effect, which leads to increase the production that relieves pain and stiffness in muscles and joints. IR also strengthens the elasticity of the connective tissue and increases lymph and blood circulation. When treating the skin in, for example, the face with IR, clogged pores are opened, gray and glossy skin gets a new and finer luster. Technology 3: Bipolar RF(radio frequency) Bipolar RF makes water molecules in the fat revolve with high speed to produce friction and shock, then triglyceride go out from fat. RF energy with 1-10M could get to 4-15mm skin depth, which makes every layer get heat evenly. The new collagen makes skin turn tighten. This Bipolar RF makes the reorganizing fat cells connect more closely, stimulate the collagen re-grow, avoiding flabby skin after slimming treatment. Technology 4: Vacuum massage The vacuum massages lift, mold and massage the skin deep and on the surface. The massage also increases the blood circulation, which in turn leads to the release of fat from the fat cells. The massage further provides a tightening of the skin. Technology 5: Mechanical roller massage The mechanical roller massage works profoundly on densified connective tissues. The mechanical massage rollers enhance the skin's cell-generating activity, resulting in thickened fat deposits being drained. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Beijing QM Medical Co., Ltd.
Room 409, Floor 4, No.113, Kaifang Road, HuaiRong District, Beijing 100000 China 2/2/24 6:35 GMT
Slimming Leg Fat Slimming Beauty Slimming Equipment Shaper Body Slimming Va
Shape II+ : Applications: 1) Fat and Cellulite Reduction 2) Body Contouring 3) Facial Lifting and Body Tightening 4) Skin Texture improvement 5) Lips and eye contours and wrinkle removal 6) Mechanical Massage Working Principle: Technology 1: Cavitation 40KHz Cavitation technology in itself means that the ultrasound causes the fat cells to vibrate so fast (high frequency) so vacuum bubbles are formed in the cell. As a consequence, the outer casing of the fat cells (the membrane) is "blown out" and the fat ends outside the cells. Outside of the membrane, the fat can be broken down to rapidly accessible energy, which is then taken up in the blood or transported by lymph nodes, after which they are either burned or stored in other fat cells elsewhere in the body. Technology 2: 940nm infrared light Infrared light (IR) has a direct and very positive effect on muscles and joints. IR increases the oxygenation in the cells and gives a warming effect, which leads to increase the production that relieves pain and stiffness in muscles and joints. IR also strengthens the elasticity of the connective tissue and increases lymph and blood circulation. When treating the skin in, for example, the face with IR, clogged pores are opened, gray and glossy skin gets a new and finer luster. Technology 3: Bipolar RF(radio frequency) Bipolar RF makes water molecules in the fat revolve with high speed to produce friction and shock, then triglyceride go out from fat. RF energy with 1-10M could get to 4-15mm skin depth, which makes every layer get heat evenly. The new collagen makes skin turn tighten. This Bipolar RF makes the reorganizing fat cells connect more closely, stimulate the collagen re-grow, avoiding flabby skin after slimming treatment. Technology 4: Vacuum massage The vacuum massages lift, mold and massage the skin deep and on the surface. The massage also increases the blood circulation, which in turn leads to the release of fat from the fat cells. The massage further provides a tightening of the skin. Technology 5: Mechanical roller massage The mechanical roller massage works profoundly on densified connective tissues. The mechanical massage rollers enhance the skin's cell-generating activity, resulting in thickened fat deposits being drained. Five Core Technologies Professional makes us different Minimum Order: 1 bags Contact:
Phone: Fax: Email: Beijing QM Medical Co., Ltd.
Room 409, Floor 4, No.113, Kaifang Road, HuaiRong District, Beijing 100000 China 2/2/24 6:33 GMT
Hot Selling Machine Body Sculpting for Beauty Equipment Weight Loss Body Sl
Model:ishape III Applications: 1. Intensive physical biolysis to remove fat 2. Excess fat cell melted, Body circumference reduction 3. Body slimming, Body contouring, Body Shaping 4. Cellulite reduction, Massage 5. Skin tightening, Eyelid Area Treatment, Dark Circles 6. Smooth fatigue, Wrinkle removal, Skin Rejuvenation, Face Lifting 7. Remove obstruction from channels and collaterals 8. Promote and accelerate the body's metabolism Working Theory: 940nm Infrared laser reduces skin impedance by heating skin and RF energy penetrates deeply into connective tissue; The synergistic combination of infrared laser and conducted Bipolar RF energies increase the oxygen intracellular diffusion by heating the skin Vacuum plus specially designed rollers manipulate leads RF penetration to be even 5-15mm. At the same time, Cavitation and Rollers mechanical tissue manipulation nips and stretches fibrillar connective tissue, effectively breaks down subcutaneous fat as well as extruded capillary vessel, Increase lymphatic drainage, promotes metabolism and reduces or shrinks the size of the actual fat chamber and greatly improved body contouring effect; The technology that vacuum folds skin makes RF energy penetrate a specific folded skin, greatly improve effect and safety, even for the upper eyelid area treatment. Technology Introduction Technology 1: Cavitation 40KHz Cavitation technology in itself means that the ultrasound causes the fat cells to vibrate so fast (high frequency) so vacuum bubbles are formed in the cell. As a consequence, the outer casing of the fat cells (the membrane) is "blown out" and the fat ends outside the cells. Outside of the membrane, the fat can be broken down to rapidly accessible energy, which is then taken up in the blood or transported by lymph nodes, after which they are either burned or stored in other fat cells elsewhere in the body. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Beijing QM Medical Co., Ltd.
Room 409, Floor 4, No.113, Kaifang Road, HuaiRong District, Beijing 100000 China 2/2/24 6:32 GMT
100A AC Current Clamp GFUVE HQ15 15mm Split Core CT Probe sensor
The HQ15 100a current probe sensor is designed for easy installed in tight spaces and without the need for dismantling the primary busbar or cables. The sensing head uses sliding push-fit clamp structure, safety isolation to avoid the user to contact with charged objects directly. It complies with CE standards and meets 300V CAT III safety class. This model HQ15 current sensor is a high accuracy mini current probe for measurements up to 130A AC. This current probe uses a special magnetic core to provide higher accuracy and lower phase shift. The HQ15 Series is an excellent probe sensor to be used in power and low level current measurement applications. Electrical parameters Ratio: 1000: 1 , 2000:1, 2500:1 (customized) Accuracy class: 0.1%, 0.2% Primary current: 0 - 5A AC and 0-100A AC Signal output: 10mV/A, 1mV/A, 1mA/A Secondary voltage: 0 - 0.05V AC, 0 - 0.1V AC, 0 - 1V AC; Secondary current: 0-5mA or 0-100mA AC Max. Cont. Input current: 130A Load capacity: ≤10Ω, standard 4Ω Over voltage category: CAT III 600V Frequency range: 40Hz-5KHz Dielectric strength: 3KV 50Hz/60Hz at 1minute Temperature range: -40°C to +55°C Output: 2.5 meter cable with D01 or BNC connector Max. voltage not insulated conductors: 600 V Standard: EN 61010-1, EN 61010-2-032, EN 61010-2-031 IEC60044-1, & IEC61869-2, 600V CAT III Installation: clamp type Range: 5A, 10A, 100A optional Output mode: lead output(2.5m) Connector: 4mm banana, BNC, signal cable(2 cores),customized Accuracy (100A Range) 0-100mA: ≤0.5% 100mA-1A: ≤0.2% 1-130A: ≤0.1% Phase Shift(100A Range) 0-100mA: ≤0.5° 100mA-10A: ≤0.2° 10-130A: ≤0.1° Mechanical parameters Dimensions (L x W x H) (mm): 46 x 162 x 25 Weight (g): 320 Holding wire diameter (mm): φ15 Max. jaw opening (mm): 13 Jaw color: Black Material: PC+ABS, UL94 V0 Minimum Order: 3 bushels Contact:
Phone: Fax: Email: Beijing Gfuve electronics co.ltd.
Bldg.2-1111, Joy MansionNo.99 Chaoyang North Road, Chaoyang District, Beijing Beijing 100024 China 2/2/24 6:24 GMT
Hot Sale Non-Surgical 80K 40K Cavitation System Body Slimming Vacuum RF Rad
iShape I Professional Vacuum Roller Cellulite Body Massager Slimming Fat Burning Endermology Vacuum RF Slimming Machine Applications 1. Skin Tightening 2. Wrinkle Removal 3. Eyes' area treatments 4. lncrease skin elasticity 5. Fat and cellulite reduction 6. Face wrinkle removal & lifting 7. Warm vacuum cellulite massage 8. Body slimming, contouring & shaping 9. Promote cell metabolism, improveblood circulation Working Principle 940nm Infrared laser reduces skin impedance by heating skin and RF energy penetrates deeply into connective tissue; The synergistic combination of infrared laser and conducted Bipolar RF energies increase the oxygen intracellular diffusion by heating the skin Vacuum plus specially designed rollers manipulate leads RF penetration to be even 5-15mm. At the same time, Cavitation and Rollers mechanical tissue manipulation nips and stretches fibrillar connective tissue, effectively breaks down subcutaneous fat as well as extruded capillary vessel, Increase lymphatic drainage, promotes metabolism and reduces or shrinks the size of the actual fat chamber and greatly improved body contouring effect; The technology that vacuum folds skin makes RF energy penetrate a specific folded skin, greatly improve effect and safety, even for the upper eyelid area treatment. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Beijing QM Medical Co., Ltd.
Room 409, Floor 4, No.113, Kaifang Road, HuaiRong District, Beijing 100000 China 2/2/24 6:20 GMT
Newest Alexandrite Laser Hair Removal Long Pulse 1064nm ND YAG 755nm Alexan
Appliction: Hair removal on all skin and hair types Spider veins Telangiectasia and telangiectatic matting on the face and legs Nail fungus treatment Removal of epidermal pigmented lesions (Sun-damaged skin, Age spots, Freckles) Treatment of vascular anomalies Working Principle Ten times effect of traditional Q-switch nanosecond laser Pico second laser is used to break up pigment particles under skin. Then, lymphatic system latches onto the pigment particles and carries them away to get excreted . Minimum Order: 1 bags Contact:
Phone: Fax: Email: Beijing QM Medical Co., Ltd.
Room 409, Floor 4, No.113, Kaifang Road, HuaiRong District, Beijing 100000 China 2/2/24 6:08 GMT
20A AC Current Clamp GFUVE Q8A2 8mm Split Core CT Transformer Probe sensor
The model Q8A2 permalloy core ac current clamp ct with high accuracy up to 0.1% has been designed for use with energy meter tester, multimeters, recorders, power analyzers, safety testers etc. It has low phase shift for power measurement, greatly suitable for electric energy meter calibrator and oscilloscope. This Q8A2 clamp ct can convert 0 - 10A AC current to 0 - 10mA AC current with real shape, max 20A measurement, but with harmonic measurement function. It is suitable for leakage current measurement in the field. Electrical parameters Ratio: 1000: 1, 2000:1 or 2500:1 (customized) Accuracy class: 0.1 %,0.2% Primary current: 0 - 5A AC, 0 - 10A AC, 0 - 20A AC Secondary current: 0 - 10mA AC or 0 - 100mV AC (customized) Max. Cont. Input current: 6A, 12A, 24A Load capacity: ≤20Ω , Standard 4Ω Over voltage category: CAT III 600V Output signal (AC current): From 0 to 10mA AC at nominal input current Output signal (AC voltage): From 0 to 100mV AC at nominal input current Signal ratio: 1mA/A, 1mV/A, 10mV/A, 100mV/A Frequency range: 10Hz-200KHz Dielectric strength: 3KV 50Hz/60Hz at 1 minute Temperature range: -20°C to +55°C Output: 2.5 meter cable with D01 connector Max. voltage not insulated conductors: 720 V Standard: EN 61010-1, EN 61010-2-032, EN 61010-2-031 IEC60044-1, & IEC61869-2, 600V CAT III Installation: Clamp type Output mode: Lead output (2.5m) Connector: BNC, 4mm banana, Audio plug,customized Mechanical parameters Dimensions (L x W x H) (mm): 45x158x25 Weight (g): 250 Holding wire diameter (mm): φ8 Max. jaw opening (mm): 8 Jaw color: Black Material: PC+ABS+Polycarbonate, UL94 V0 Minimum Order: 3 bushels Contact:
Phone: Fax: Email: Beijing Gfuve electronics co.ltd.
Bldg.2-1111, Joy MansionNo.99 Chaoyang North Road, Chaoyang District, Beijing Beijing 100024 China 2/2/24 6:04 GMT
20A AC Current Clamp GFUVE Q8A1 8mm Split Core CT Transformer Probe sensor
The model Q8A1 current probe/clamp on ct is based on AC transformer technology for use in measurement of AC current, it is suitable for 5A, 10A cable online measurement. With measurement range of 1 mA to 10A AC and frequency range from 40Hz to 200KHz, it has a high accuracy class of 0.1%. It suits for oscilloscope, power quality analyzer, electric energy meter calibrator. Easy to operate everywhere. its technical standard according to EN 61010-1, EN 61010-2-032, IEC60044-1. This model Q8A1 clamp on current probe have been used in many instrument manufacturers. Electrical parameters Ratio: 1000: 1, 2000:1 or 2500:1 (customized) Accuracy class: 0.1 %,0.2% Primary current: 0 - 5A AC, 0 - 10A AC, 0 - 20A AC Secondary current: 0 - 2.5mA, 0-5mA, 0-10mA, 0-20mA AC (customized) Secondary voltage: 0 - 50mV, 0-100mV, 0-200mV, 0-1V, 0-5V AC (customized) Max. Cont. Input current: 24A Load capacity: ≤20Ω , Standard 4Ω Over voltage category: CAT III 600V Output signal (AC current): From 0 to 10mA AC at nominal input current Output signal (AC voltage): From 0 to 100mV AC at nominal input current Signal ratio: 1mA/A, 1mV/A, 10mV/A, 100mV/A Frequency range: 10Hz-200KHz Dielectric strength: 3KV 50Hz/60Hz at 1minute Temperature range: -20°C to +55°C Output: 2.5 meter cable with D01 connector Max. voltage not insulated conductors: 720 V Standard: EN 61010-1, EN 61010-2-032, EN 61010-2-031 IEC60044-1, & IEC61869-2, 600V CAT III Installation: Clamp type Output mode: Lead output (2.5m) Connector: BNC, 4mm banana, Audio plug,customized Mechanical parameters Dimensions (L x W x H) (mm): 42.6x122.5x23 Weight (g): 250 Holding wire diameter (mm): φ8 Max. jaw opening (mm): 8 Jaw color: Black Material: PC+ABS+Polycarbonate, UL94 V0 Minimum Order: 3 bushels Contact:
Phone: Fax: Email: Beijing Gfuve electronics co.ltd.
Bldg.2-1111, Joy MansionNo.99 Chaoyang North Road, Chaoyang District, Beijing Beijing 100024 China 2/2/24 5:48 GMT
China sundry elevator
Dundry elevator of LD dumbwaiter appears modern and imposing. It is full of the rational aesthetics.What is more ,the multiple styles of the car materials are available for the customers’ free selections.It maximumly satisfies the diverse and individual choices for the construction style and taste Contact:
Phone: Fax: Email: SUZHOU FUJILF ELEVATOR CO.,LTD.
Fenhu Development Zone, Wujiang, Suzhou City, Jiangsu Province, China Suzhou 215200 China 2/2/24 5:44 GMT
Goods Elevator
Goods elevator adopts VVVF control system and USES a new generation frequency converter to optimize the control circuit, so that the elevator has a good and smooth running curve, stable starting and braking, and features reasonable layout, high leveling precision, low running noise and strong anti-interference ability. Contact:
Phone: Fax: Email: SUZHOU FUJILF ELEVATOR CO.,LTD.
Fenhu Development Zone, Wujiang, Suzhou City, Jiangsu Province, China Suzhou 215200 China 2/2/24 5:42 GMT
Car Elevator
car elevator, the introduction of mature international auto lift technology, through the absorption, transformation and upgrading, and development and production of automotive lifts, advanced technology ensures that caused by uneven capsules mechanical traction system of heavy load caused by noise and capsules shaking this disadvantage does not exist, the characteristics of this series of products was optimized. Contact:
Phone: Fax: Email: SUZHOU FUJILF ELEVATOR CO.,LTD.
Fenhu Development Zone, Wujiang, Suzhou City, Jiangsu Province, China Suzhou 215200 China 2/2/24 5:39 GMT
High Quality Indoor Type Moving Walk
By High technology,innovative,attractive design and color, reliable and almost silent operation,DOOPLER provide passenger of flows quickly, comfortably and with safety service,as well as creating visual bridges in high-rise shops,large shopping centers, airports, metro,railway stations and city centre. Contact:
Phone: Fax: Email: SUZHOU FUJILF ELEVATOR CO.,LTD.
Fenhu Development Zone, Wujiang, Suzhou City, Jiangsu Province, China Suzhou 215200 China 2/2/24 5:15 GMT
120A AC Current Clamp GFUVE XQ13 13mm Hole Handheld Split Core CT Transform
The model XQ13 100A current probe clamp is suitable for 0A-100A cable online measurement, it belongs to high performance transducer field. Up to 0.1% accuracy class, this current probe clamp is suitable for most oscilloscopes. Current signal can be measured directly. Suitable for accurate measurement of AC current using the permalloy core material. Frequency range 40Hz-200KHz, with standard 2.5 meter cable with D01 connector. EN 61010-1, EN 61010-2-032, IEC60044-1 Standard. Electrical parameters Ratio: 1000: 1, 2000:1 or 2500:1 (customized) Accuracy class: 0.1%, 0.2% Primary current: 0 - 100A AC Secondary current: 0 - 100mA AC (customized) Max. Cont. Input current: 120A Load capacity: ≤20Ω , Standard 4Ω Over voltage category: CAT III 600V Output signal (AC current): From 0 to 100mA AC at nominal input current Output signal (AC voltage): From 0 to 5V AC at nominal input current Signal ratio: 1mA/A, 1mV/A, 10mV/A, 100mV/A Frequency range: 40Hz-200KHz Dielectric strength: 3KV 50Hz/60Hz at 1 minute Temperature range: -20°C to +55°C Output: 2.5 meter cable with D01 connector Max. voltage not insulated conductors: 720 V Standard: EN 61010-1, EN 61010-2-032, EN 61010-2-031 IEC60044-1, & IEC61869-2, 600V CAT III Installation: Clamp type Output mode: Lead output (2.5m) Connector: BNC, 4mm banana, Audio plug,customized Mechanical parameters Dimensions (L x W x H) (mm): 48 x 179 x 27 Weight (g): 325 Holding wire diameter (mm): φ13 Max. jaw opening (mm): 13 Jaw color: Red, yellow, blue, green, black Material: PC+ABS+Polycarbonate, UL94 V0 Minimum Order: 3 bushels Contact:
Phone: Fax: Email: Beijing Gfuve electronics co.ltd.
Bldg.2-1111, Joy MansionNo.99 Chaoyang North Road, Chaoyang District, Beijing Beijing 100024 China 2/2/24 4:20 GMT
Heavy-Duty Type Escalator
Overloaded bus type escalator is a specially designed for public transport tailored overloading type escalators, excellent product quality, superior performance and leading security, can fully meet the high hoisting height, traffic was great, transportation time long rigid bearing requirement, for the subway, railway stations, airports and other public transportation sites to provide the best solution. Contact:
Phone: Fax: Email: SUZHOU FUJILF ELEVATOR CO.,LTD.
Fenhu Development Zone, Wujiang, Suzhou City, Jiangsu Province, China Suzhou 215200 China 2/2/24 4:17 GMT
Observation Elevator
The high integrated 32-bit dual CPU of the high integrated intelligent control system, the master and slave cpus monitor each other, which improves the data processing speed, functions and reliability to a greater extent.The high- precision car displacement detection technology can achieve almost zero - to - zero level accuracy, so that passengers in and out of the car on the ground. Contact:
Phone: Fax: Email: SUZHOU FUJILF ELEVATOR CO.,LTD.
Fenhu Development Zone, Wujiang, Suzhou City, Jiangsu Province, China Suzhou 215200 China SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)
© 1996-2026 IMEXBB.com. All rights reserved.
|
|